MAINTENANCE
UV Clarifier
To maximize the performance of the UV clarifier, periodically
disassemble the filter to clean dirt and debris from the
exterior of the glass tube and inside light housing. Check the
UV bulb to make sure that it has nor burned out. Replace
the bulb as necessary, or after every season.
Step 1. Disconnect the UV
Clarifier from the outlet.
Allow a sufficient time to
pass for the light to cool
before disassembling the
light.
Step 2. Rotate the locking
ring counterclockwise to
remove the lamp holder.
Step 3. To replace the
bulb, remove the bulb
holder. Carefully remove
the old bulb by pulling firmly
on the base. Carefully
install the new bulb and
put the bulb holder back in
place.
Step 4. Reinstall the lamp
holder and locking ring.
NOTE: This UV clarifier
includes a safety feature
that will not allow the light
to turn on if the lamp holder
or locking ring are not
securely fastened.
Step 5. Reconnect the
UV Clarifier to the power
source.
Wait several seconds from
the light to turn on. Check
the indicator light to varifiy
if the light is functioning
correctly.