The appliance is dotated with
Wheels and Handle. Wheels, Han-
dle and the mounting accessories
are found in the shipping carton.
In The carton you find the follow-
ing items:
1)
1 body of the heater
2)
1 handle
3)
1 wheel support frame
4)
1 axle
5)
2 wheels
6)
4 screws
7)
4 nuts
8)
4 washers
9)
2 cap nuts
10) 2 lock washers
To get a good ventilation a fresh air
opening of at least 0.01 m
necessary. It should be in propor-
tion to the thermal power of the
appliance
Minimum area for air openings
Model
m
2
K 20 C
0.15
K 30 C
0.25
K 40 C
0.35
General functioning
The air pump forces air through the
air line up to the burner head noz-
zle. Air under pressure causes fuel
to be sucked from the tank. Fuel
mixed with air is then sprayed into
the combustion chamber.
The fan, run by a motor, pushes air
into and around the combustion
chamber.
12
4. Assembly
To assemble the heater, proceed
as follows (see ill.1):
Slide axle (4) through wheel sup-
port frame (3). Install in the follow-
ing order: wheels (5), and cap nuts
(9) on axle ends, by tapping lightly.
Place heater on wheel support
frame and line up holes on the fuel
tank flange with holes on wheel
support frame.
Insert screws and washers through
handles, fuel tank flange and wheel
support frame. Attach nut finger
tight after each screw is inserted,
then tighten all nuts firmly.
5. Setup
For use in construction industry and
2
/kW is
in agriculture the safety regulations
in force must be respected. In par-
ticular, the following safety distanc-
es from flammable materials should
be taken in consideration:
Side:
Air intake side:
Top:
Air outlet side:
6. Instructions for use
A stream of air at high temperature
flows out of the front section of the
appliance.
The flame-out control system ig-
nites the flame and stops the heat-
er if malfunctioning.
Start-up
Fill fuel tank with clean diesel or
paraffin.
Fig. 1
Inspections
According to working conditions,
the appliance should be inspected
by the Technical Service at least
once a year.
0.60 m
Prior to start-up, operating person-
0.60 m
nel must check for any non-compli-
1.50 m
ance with rules of use, safety and
protection.
3.00 m
Plug power cord of heater into a
standard 230 V 50 Hz outlet, prop-
erly grounded.
Turn switch to "ON"(I)
Lock-out
In case of defective ignition or over-
heating the flame-out control sys-
tem shuts the heater off. If this
occurs: