3
COMMISSIONING
2
Male connector connection: pin assignment
Cable: core color
Image: B
Only apply voltage/switch on the power supply (V
tions have been completed. The green LED indicator lights up on the sensor.
Explanations of the connection diagram (Graphic B):
Switching outputs Q and /Q (according to Graphic B):
WTB4S-3Exxxx and WTB4S-3Fxxxx
D: dark-switching, output (Q) switches off when an object is present in the sensing
range.
WTB4S-3P1362 and WTB4S-3Px1xx
WTB4S-3N1362 and WTB4S-3Nx1xx
L: light switching, output (Q) switches when an object is present in the sensing ran‐
ge.
WTB4S-3P1161 and WTB4S-3N1161
WTB4S-3Px261 and WTB4S-3Nx261
ANT: complementary outputs Q and Q/
3
Align the sensor with the object. Select the position so that the red emitted light
beam hits the center of the object. You must ensure that the optical opening (front
screen) of the sensor is completely clear [E]. We recommend making the adjust‐
ments using an object with a low remission.
Image: E
4
> 0 V) once all electrical connec‐
S
8012134.10DT | SICK