Operating Instructions
L4000 system
WARNING
Note
Note
Tab. 4: Scanning range on
usage of deflector mirrors
8010009/YTA2/2016-05-02
Subject to change without notice
Installation and mounting
4.3

Mounting the sensors, L4000, L400

You can mount the sensors either directly in appropriate holes or with
the aid of the mounting brackets available (see Ordering information,
p. 107 and appendix).
Special features to note during mounting:
= During mounting, make sure that sender and receiver are aligned
correctly. The optical lens systems of sender and receiver must be
located on the same optical axis.
= Take suitable measures to attenuate vibration if the shock
requirements are above the values given in the chapter 9
"Technical data, Data sheet, safety evaluation device ".
= During mounting, it is imperative that chapter 4.1.1 "Safety
distance for access protection", 4.1.2 "Minimum distance to
reflective surfaces" and 4.1.3 "Multiple protection".

4.3.1 Deflector mirror

Using the L4000 system and deflector mirrors, multiple sided access
guarding can be realised (Fig. 13).
The usage of deflector mirrors reduces the useable scanning range of
the L4000 system as per the table.
The usage of more than 2 mirrors (Fig. 14) requires very precise
alignment. In this case use the alignment aid AR60 (see chapter 6.2).
Number of
Scanning range with
mirrors
L400 sensors
1
8 m
2
6.4 m
3
5.1 m
4
4 m
 SICK AG • Industrial Safety Systems • Germany • All rights reserved
Chapter 4
Scanning range with
L4000 sensors
48 m
38.4 m
30.7 m
24.5 m
en
81