Setting Output Data; Setting Door Relay Strike Time; Setting Alarm Signal Output Time; Setting Door Open Detection - PRASTEL Fingerkey Manual Del Usuario

Lector de huellas digitales y unidad de control de accesos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 66

Setting output data

The output programmable data is formed by user ID as
default setting, and could be output with Wiegand 26 or
Wiegand 34.
Press: 3 user ID # new data #
Note
The data must be of 10 digits and within 0000000001-
GB
4294967295

Setting Door Relay Strike Time

The door relay output can be operated as either normally
opened or normally closed, a maximum current of 10 ampere
can pass through the relay if used as normally opened or 5
ampere if normally closed. The door relay time can be set
from 0 seconds to a maximum of 99 seconds. The factory
default setting is 6 seconds and can be changed through the
keypad.
Press: 4 new time from 00 to 99 seconds #

Setting Alarm Signal Output Time

Press: 5 new time from 00 to 99 minutes #

Setting Door Open Detection

Press: 6 0 0 # to disable this function (factory setting)
Press: 6 0 1 # to enable this function.
- 27 -