Faucet leaks from tub spout/showerhead:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge EP78407. Check condition
of lower O-rings and replace if necessary RP14414.
See Helpful Hints 1, 2, & 3.
If leak persists:
SHUT OFF WATER SUPPLIES.
Replace valve cartridge EP78407.
See Helpful Hints 1, 2, 3 & 5.
Unable to maintain constant water temperature:
Replace valve cartridge EP78407 or follow
instructions in Helpful Hints 1, 2, 4 & 5.
Helpful Hints:
1. Before removing valve cartridge assembly for any
maintenance, be sure to note the position of the
rotational limit stop on the cap. The valve cartridge
assembly must always be put back in the same
position. BE SAFE! After you have finished the
installation, turn on valve to make sure COLD WATER
FLOWS FIRST.
2. To remove valve cartridge from body, shut off
water supplies and remove handle and bonnet
nut. Do not pry the valve cartridge out of the body
with a screwdriver. Place handle on stem and rotate
counterclockwise approximately 1/4 turn after the stop
has been contacted. Lift valve cartridge out of body.
3. To remove seats and springs, remove valve
cartridge. Separate cap assembly from the
housing assembly by rotating the cap assembly
counterclockwise 90
housing assemblies. Remove seats and springs and
replace. Place the largest diameter of the spring
into the seat pocket first and then press the tapered
end of the seal over the spring. Reassemble valve
cartridge and replace in body following instructions
given in 1 above.
4. If the water in your area has lime, rust, sand or
other contaminants in it, your pressure balance
valve will require periodic inspection. The frequency
of the inspection will depend on the amount of
contaminants in the water. To inspect valve cartridge
remove it and follow the steps in note 1 above.
Turn the valve to the full mix position and shake the
cartridge vigorously. If there is a rattling sound, the
unit is functional and can be reinstalled following
instructions given in note 1 above. If there is no rattle,
replace valve cartridge EP78407.
5. Push disc until fully seated. See page 10 for
more details.
To order replacement parts, visit
www.deltafaucet.com or call
1-800-345-DELTA (3358)
Care should be given to the cleaning of this
product. Although its finish is extremely durable, it
can be damaged by harsh abrasives or polish. To
clean, simply wipe gently with a damp cloth and
blot dry with a soft towel.
(degrees). Separate cap and
o
14 T20 Series Maintenance
To change batteries:
A.
Using an Allen wrench to loosen the set screw (1),
remove the handle from the stem. Note: If no set
screw hole - handle may have cap with screw.
B.
1
Remove the escutcheon (1) by rotating it
counterclockwise until it can be pulled from the
backplate. Carefully, slide the escutcheon over
the sleeve and remove.
C.
1
2
Remove battery cover (1) by pushing in the direc-
tion of the arrow. Remove old batteries and insert
3 new "AAA" batteries (2) making sure to orient in
proper direction. Reinstall parts in reverse order.

Cleaning and Care

Warning: Scrubbing Bubbles
and Lysol
Basin Tub and Tile Cleaner must not be
®
used on the clear knob handles and levers. Use
of these cleaners can result in cracked or severely
damaged handles. If overspray gets onto the
handles, immediately wipe them dry with a soft
cotton cloth
11
1
Bathroom Cleaner
®