IMPIANTO ELETTRICO - ELECTRICAL SYSTEM - SYSTÈME ÉLECTRIQUE - ELEKTRISCHE ANLAGE -
INSTALACIÓN ELÉCTRICA - ЭЛЕКТРИЧЕСКАЯ СИСТЕМА - ΗΛΕΚΤΡΙΚΗ ΜΟΝΑΔΑ -
A - MAIN POWER SUPPLY (can be ordered as come optional)
•
Install in the safety zone: Z3
•
Input: 100-240 V ac, 50÷60 Hz
•
Output: 12 V dc, 4,5 A (max)
•
Standard: IEC60950-1
•
Safety: SELV Class II
B - TRACK
C - REMOTE CONTROL (can be ordered as come optional)
•
Install in the safety zone: Z1-Z2-Z3
•
Protection class: IP66
•
Battery: CR2032
D - POWER SUPPLY/CONTROL UNIT PER SENSOR PIR (can be ordered as optional)
•
Install in the safety zone: Z3
•
Power: < 1 W
•
Input: 230 V ac
•
Safety: IP20 / II / CE
•
Service temperature: -25°C÷50°C
E - PRESENCE SENSOR "PIR" (can be ordered as come optional)
•
Install in the safety zone: Z1-Z2-Z3
•
Safety: IP65 / II / CE
•
Service temperature: 0°C÷45°C
•
Connection between A-B
Length max = 8 m
Poles = 2
Section = 20-22 AWG
Cable diameter: 4÷6 mm (PG7)
•
Connection between D-B
Length max = 10 m
Poles = 2
Section = 20-22 AWG
Cable diameter: 4÷6 mm (PG7)
WARNING:
- the connection to a cut out switch with intervention current not greater than 30mA is mandatory.
- on the supply cable "L+N" (not included), to guarantee compliance with the requirements of Electromagnetic
Compatibility, it is necessary to position the following ferrite: Trademark: Fair-Rite Products Corp - Model:
431164281 or a component with similar characteristics.
DATA FOR THE ELECTRICAL SYSTEM
ELECTRICAL CONNECTIONS DATA
22