Specifications; General; Characteristics; Ac Current (Automatic Ranges) - Chauvin Arnoux F 62 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

English
5.

SPECIFICATIONS

5.1. General

Only values with tolerances or stated limits are
guaranteed. Values without tolerances are stated for
information only.

5.2. Characteristics

The precision is ± [% of reading (L) + number of
representation units (digits or D)] under the reference
conditions (see Appendix).

5.2.1. AC current (automatic ranges)

R anges
R esolution
A ccuracy (50H z~1K H z)
10A
1m A
1.2%±5cts(50~60Hz)
2.5%±5cts(60~1000Hz)
80A
10m A
5% ±5 cts (50~60Hz)
80~100A
10m A
Overload protection: 150 A
rms

5.2.2. mAC current (automatic ranges)

R anges
R esolution
A ccuracy (50H z~1K H z)
60m A
10uA
1.2%±5cts(50~60Hz)
2.5%±5cts(60~1000Hz)
600m A
100uA
Overload protection: 150 A
rms

5.2.3. AC voltage (automatic ranges)

R anges
R esolution
A ccuracy (50H z~1K H z)
600V
0.1V
1.5%±5cts
Input impedance: 1 MΩ
Overload protection: 660 Vrms

5.2.4. DC voltage (automatic ranges)

R anges
R esolution
600V
0.1V
1.0%±2cts
Input impedance: 1 MΩ
Overload protection: 660 Vrms
31
A ccuracy
F 62

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

F 65