Installation Instructions – LDA2B/LDSQAB/LDA2BCP/LDSQABCP Commercial Recessed Adjustable LED
Figure 1.
Catalog Number
LDA2B
LDA2BCP
LDA2B (Rimless)
LDSQA2B
LDSQA2BCP
LDSQA2B (Rimless)
INSTALLATION
Rough-In Section
1.
Fixture Attachment Method: Install fixture into ceiling
cavity using 1/2˝ electrical conduit. Use 3/4˝ channel,
1-1/2˝ channel, 1/8˝ x 1/2˝ bar stock, or T-bar fasteners
as mounting rails (furnished by others) by inserting
them through hanger brackets at both sides.
2.
Remove overspray protector. Adjust (4) #6 screws such
that the bottom of the collar if flush with the finished
ceiling. If the ceiling is greater than 7/8" [22.0mm] and
less than 1-1/4" [31.8mm], a collar adaptor is required
(see figure 2a and 2b).
3.
Hanger bar bracket should be adjusted as needed
(screws, see figure 3).
4.
See chart above for appropriate cut-outs (square vs.
round, standard vs. rimless).
5.
For situations where the housing lid is accessible after
housing installation, see figure 4 for removal (removing
the housing lid makes many of the upcoming tasks
easier to perform).
2
2
COOPER LIGHTING SOLUTIONS IB520064ML
Ceiling
Aperture
Cutout
2-3/4"
3-1/8"
2-3/4"
3-1/8"
2-3/4"
3-1/4"
2-2/4" SQ
3-1/4" SQ
2-2/4" SQ
3-1/4" SQ
2-2/4" SQ
3-3/8" SQ
Installation instructions
Fixture
Lumens
Height
5.5"
500, 1000,1500, 2000
5.5"
500, 1000,1500, 2000
5.5"
500, 1000,1500, 2000
5.5"
500, 1000,1500, 2000
5.5"
500, 1000,1500, 2000
5.5"
500, 1000,1500, 2000
Collar Flush With Ceiling
Figure 2a.
Collar Extension
Flush with Ceiling
Figure 2b.
Ceiling Type
500, 1000, 1500, 2000
TYPE IC
Collar Adjustment Screws