Operational aspects:
• Overloading of the KCF impairs the
separating efficiency, shortens the filter
service life and can lead to overflowing.
• Only use cartridge sets for replace-
ment. The approved cartridges are
identified on page 18.
Intended use:
The KCF oil-water separator is used for
treating non-emulsified condensate in
compliance with the legal regulations.
Feed fluid:
Compressor condensate
Condensate/ambient temperature:
34 ... 140 °F
Discharged fluid:
Cleaned condensate with mineral oil hy-
drocarbon content far below the statutory
limit (see above).
Will meet standard EPA regulations.
Check with your local POTW for require-
ments.
To Begin operation:
Step 1. Remove the lid by loosening the 4 screws
on lid top.
Step 2. Check the cartridge area, make sure the fac-
tory plastic bag has been removed.
Step 3. Re-install the lid with the 4 screws. Make sure
not to over tighten.
Step 4. MUST BE COMPLETED before introducing
compressed air condensate to unit. Pour water
into the unit from the top through the pressure
relief chamber area.
Step 5. Stop pouring the water (approx. 18 gallons)
when it starts to come out at the water outlet that is
located on the side of the unit.
Step 6. Wait approximately 5 mins so the cartridge
will adsorb some of water & add additional water
to the unit until you see water coming out of the
outlet again. Once this has been accomplished the
unit will be recharged and ready for full operation.
Step. 7 You know can introduce condensate into unit
via the multiple inlet adaptor located on the top lid.
The KCF is ready for operation:
- Feed in condensate
Checking for leaks
• Inspect hoses and connections, tighten
screws where necessary or replace
parts.
• Container
Contact KAESER in the event of leak-
age.
KCF 100