120Vac /60 Hz
Control unit with integrated receiver - Instructions p. 4
Central de mando con receptor radio - Istrucciones p. 7

Publicidad

Tabla de contenido
loading

Resumen de contenidos para RSI QC zero

  • Página 1 120Vac /60 Hz Control unit with integrated receiver - Instructions p. 4 Central de mando con receptor radio - Istrucciones p. 7...
  • Página 2 These instructions contain important information on the installation and the use of the QC00 unit. Please keep them even after installation. Do not start installing the QC00 unit without having first read these instructions. The installation can only be done by a qualified technician. In order to conform to the rules in force, the installation must include on its power supply line a differential magnetothermic switch with minimum distance between the contacts of at least 3mm.
  • Página 3 LED “ON” LED “OK” JA JB 1 2 3 4 5 7 8 9 10 24 Vac 115 V~ 60 Hz 500 W...
  • Página 4 1. LOW VOLTAGE CONNECTIONS SS = PUSH BUTTON START/STOP (USUALLY OPEN) Must be connected on the terminals 7 (com) and 8 (SS). To choose the impulsive or dead man (in closing) working logic follow the procedure in paragraph 11. STOP (USUALLY CLOSED) Must be connected on the terminals 7 (com) and 9 (STOP).
  • Página 5: Reset Procedure

    4.2 PROGRAMMING THE TRANSMITTERS - STOP functions Fig. 1 Fig. 2 This procedure links a transmitter radio signal to the STOP function. 1. Insert the JA jumper (fig.1). The OK led is on. 2. Maintaining the STOP (ST) button pressed during the emission of the radio signal. If the STOP button has not been installed, open the contact between terminals 7 (com) and 9 while the radio signal is sent.
  • Página 6: Programming The Pause Time

    7. PROGRAMMING THE PAUSE TIME Pause Time programming allows the door to close automatically. Once memorised, the pause time can also be modified. The function can be deactivated during the pause by a signal from the transmitter. To avoid the automatic closing it is necessary to reset the unit (paragraph 8). WARNING: The RESET procedure also cancels all other programmed features! 1.
  • Página 7: Conexiones En Baja Tension

    1. CONEXIONES EN BAJA TENSION SS = PULSADOR START/STOP (NORM. ABIERTO) Debe ser conectado a los bornes 7 [com] y 8 [SS]. Para elegir la logica del funcionamiento impulsiva o hombre presente (en bajada) siga el procedimiento en el párrafo 11. STOP (NORM.
  • Página 8: Programacion De Los Transmisores - Función Stop

    Central de mando con receptor radio 4.2 PROGRAMACION DE LOS TRANSMISORES - función STOP Fig. 1 Fig. 2 Este procedimiento combina un código radio del transmisor con la función de STOP. 1. Insertar el puente en JA (fig. 1). El led OK se enciende. 2.
  • Página 9: Programacion Del Tiempo De Pausa

    Central de mando con receptor radio 7. PROGRAMACION DEL TIEMPO DE PAUSA La programación del tiempo de pausa permite a la puerta de bajarse automaticamente. Una vez memorizado, el tiempo de pausa puede ser modificado repitiendo la programación. Durante la pausa se puede desactivar el cierre automático con el envío de una señal del transmisor Para cancelar el cierre automático hay que hacer el RESET de la central (párrafo 8).
  • Página 12 693 Atkins Ave - Brooklyn, NY 11208 Email info@rollingsteeldoors.com - www.rollingsteeldoors.com Phone 718-272-4444 - Fax 718-272-4023...