• It should be replaced no later than 10 years after activation.
The battery is not replaceable.
6 • FUNCTION TABLE
No. Alarm signal
GB
1
Intermittent
alarm signal.
2
Short signal
emitted every
35 seconds.
3
No signal.
4
Short signal
emitted every
35 seconds.
5
No signal.
10
Red LED
Description
Flashes at the same
The detector's alarm is
time as the audible
triggered because smoke has
alarm signal.
been detected.
Two flashes
The alarm is muted for
alternating with
10 minutes.
the audible signal
every 35 seconds.
Flashes every 17
The 24-hour alarm memory
seconds.
will help you locate a triggered
detector.
Two flashes
Fault signal indicating that the
alternating with
battery is empty or there is a
the audible signal
malfunction.
every 35 seconds.
Two flashes every
Detector fault signal muted for
35 seconds.
12 hours.
ATTENTION: If the detector is exposed to excessive dust or water
over a prolonged period, this may trigger the alarm.
Solution
If the alarm is triggered, it can be muted for 10 min.
by pressing the button briefly (max. 2 seconds).
The alarm can be muted by removing the detector from
its base for 10 seconds or by using the test function:
press and hold the button for at least 3 seconds until a
loud, intermittent alarm signal can be heard.
The alarm memory can be deactivated by removing the
detector from its base for 10 seconds or using the test
function: press and hold the button for at least 3 seconds
until a loud, intermittent alarm signal can be heard.
The fault signal can be muted by removing the detector
from its base for 10 seconds or using the test function:
press and hold the button for at least 3 seconds until a
loud, intermittent alarm signal can be heard.
If the fault recurs, the detector must be replaced. If the
fault signal is triggered, the alarm can be muted for 12
hours by pressing the button briefly (max. 2 seconds).
The alarm can be muted by removing the detector
from its base for 10 seconds or by using the test
function:
press and hold the button for at least 3 seconds until a
loud, intermittent alarm signal can be heard.