RIB T2 Manual Del Usuario página 22

Cuadro electronico de mando para uno o dos motores monofasicos
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

G G
B B
check the leaves swinging and the opening mechanical stopper
position.
6 - After 3 seconds motor starting and for the next 10 seconds motor
working, the torque control is automatically activated. Set the
motor torque by the TORQUE Trimmer/s which varies the output
voltage to the head of the motor/s (turn clockwise to increase
torque).
7 - After other 10 seconds motor working, the low speed control is
automatically activated (DIP7 ON). Set the motor low speed by the
LOW SPEED Trimmer to select the gate leaf low speed in
approaching.
8 - Close completely the gate.
9 - Turn DIP1 to OFF position, LED DL1 turns off.
During Point C procedure, safety devices (photocells and safety
strip) are not active and the remote control cannot operate.
(#) In Point D, Point E and Point F procedures, all the safety devices
(photocells and safety strip) will be active, so they must be properly
installed and connected to the control board. Any changing of the
safety devices input state, will stop the Point D, Point E or Point F
procedure that must be repeated from the beginning.
POINT D
- PROGRAMMING FOR 2 MOTORS (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG. Button, motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the
PROG button to cut out motor M1 (time travel of M1 has now been
just stored with this operation).
5 - Motor M2 opens, automatically.
6 - Once reached the open position, let 1 second pass and press the
PROG button to cut out motor M2 (time travel of M2 has now been
just stored with this operation).The gap of time between now (stop
of motor M2) and the next pressing of the PROG. button (see step
7 below) will be then stored as waiting time for Automatic Closing
feature.
7 - Press PROG. button, M2 closes and the Automatic Closing time is
stored (see DIP3 function to enable or disable the Automatic Closing
feature). The gap of time between now (close of motor M2) and the
next pressing of the PROG. button (see step 8 below) will be stored
as time delay between motor M2 and motor M1 closing, during
normal operations.
8 - Press the PROG. button, motor M1 closes thus setting the delay
time between M2 and M1, as explained in step 7 above.
9 - The LED DL1 will turn OFF, signalling exit from the Point D
procedure.
Closing of the gate will be carried out at normal speed and only on
approaching total closing at low speed (depending on the
adjustment of LOW SPEED trimmer).
10 - Turn DIP2 to OFF position.
During Point D procedure, the safety devices (photocells and safety
strip) are active.
POINT E
- PROGRAMMING FOR 1 MOTOR (M1) (#)
ATTENTION: in order to manage one motor only, OPEN JUMPER
JP17.
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking
3 - Press PROG. button, the motor M1 opens.
4 - Once reached the open position, let 1 second pass and press the
PROG button to cut out motor M1 (time travel of M1 has now been
just stored with this operation). The gap of time between now (stop
of motor M1) and the next pressing of the PROG. button (see step
5 below) will be then stored as waiting time for Automatic Closing
feature.
5 - Press PROG. button, M1 closes and the Automatic Closing time is
stored (see DIP3 function to enable or disable the Automatic Closing
feature).
6 - The LED DL1 will turn OFF, indicating exit from the Point E
procedure. Closing of the gate will be carried out at normal speed
and only on approaching total closing at low speed (depending on
the adjustment of LOW SPEED trimmer).
7 - Turn DIP2 to OFF position.
During Point E procedure, the safety devices (photocells and safety
strip) are active.
POINT F
- PROGRAMMING OF PEDESTRIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts
blinking slowly.
4 - Press the pedestrian pushbutton PED. BUTT, motor M1 opens
5 - When the motor M1 leaf is opened enough for the pedestrian
crossing, press the pedestrian pushbutton to stop the travel (thus
defining the opening stroke of motor M1). The gap of time between
now (stop of motor M1) and the next pressing of the PROG. button
(see point 6 below) will be stored as waiting time for Pedestrian
Automatic Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, M1 closes and the
Pedestrian Automatic Closing time is stored (see DIP3 function to
enable or disable the Automatic Closing feature).
7 - Turn DIP1 to OFF position.
8 - Turn DIP2 to OFF position.
During Point F procedure, the safety devices (photocells and safety
strip) are active.
POINT G
- RADIO CODE STORING (ONLY FOR CRX)
(MAX 60 CODES)
1 - The gate must be fully closed.
2 - Turn DIP1 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the LED DL1 starts
blinking slowly. Each code must be programmed within 10 seconds.
4 - Press one of the buttons on the remote control (usually channel
A). If the remote control is stored correctly green LED DL2 (on the
T2 CRX control board) emits a flash. The 10 seconds' time within
storing radio code is automatically renewed to allow the storing of
the next remote control.
5 - To end radio code storing either press PROG. button or let 10
seconds pass. The LED DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
POINT H
- RADIO CODE ERASING (ONLY FOR CRX)
1 - The gate must be fully closed.
2 - Turn DIP1 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the LED DL1 starts
blinking slowly. Code erasing must be carried out within 10 seconds.
4 - Press the PROG. button and hold it for 5 seconds, the total
memory erasing will be indicated by two flashes of green LED DL2.
LED DL1 will blink for 10 seconds and it will be possible to store new
radio codes following the Point G procedure described above.
5 - To end radio code storing either press PROG. button or let 10
seconds pass. The LED DL1 shall stop blinking.
6 - Turn DIP1 to OFF position.
7 - Turn DIP2 to OFF position.
POINT I
- RADIO CODE FULL MEMORY TEST (only for
CRX)
1 - The gate must be fully closed.
2 - Turn DIP1 to ON position, the LED DL1 starts blinking quickly.
3 - Immediately, turn also DIP2 to ON position, the LED DL1 starts
blinking slowly.

Publicidad

Tabla de contenido
loading

Tabla de contenido