5A TEST DOOR BALANCE
FOR MODEL PDW8500 ONLY
• Release door latch. Open and release the
door. If the door tends to drop when released,
spring tension needs to be increased. If the
door tends to close, the spring tension needs
to be decreased.
• If the spring tension needs to be adjusted,
first remove 2 screws securing the dish-
washer to the underside of the countertop or
sides. Retain Screws. Carefully pull dish-
washer out from the cabinet enclosure, ap-
proximately 20", until door springs are ex-
posed.
• Always hold the dishwasher at the top when
opening the door. The dishwasher will tip
forward when the door is opened.
• See Figure 12 for adjusting spring tension.
When adjusting tension, both springs must be
set to the same position on the side brackets.
• Slide dishwasher back into the original
position.
• Check that door springs do not contact water
line, fill hose, wiring or other components.
• Reinstall the original top or side mounting
screws.
• Turn on water and power.
Pub. No. 31-30552
Note: To increase tension, use
top hole. To decrease tension
use lower hole. Adjust both
springs to the same tension
setting to correct balance.
Figure 12
Check to be sure the spring cable is routed correctly
before making spring adjustments. The cable is held in
place by "shoulders" on the pulley. See Figure 12. Check
to be sure the cable has not slipped over the pulley
shoulder and onto the axle.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
Pulley
CORRECT
Shoulder
INCREASE
DECREASE
INCORRECT
DWG. NO. 206C1559P091