Technical Characteristics; Terminal Board Connections - tau K995MA-S Guía Para La Instalación

Ocultar thumbs Ver también para K995MA-S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

2. TECHNICAL CHARACTERISTICS

Board power supply
Max motor 1 power DC
Fast acting fuse for protection of input power supply 13.5V AC (F1 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18V DC (F2 - 5x20)
Motor power supply circuits voltage
BUS circuit voltage for auxiliary devices
Logic circuits supply voltages
Operating temperature

3. TERMINAL BOARD CONNECTIONS

Terminals
Function
TRANSFORMER
L1 - L2
POWER SUPPLY
BOARD POWER
FS1 - FS2
SUPPLY
SENSITIVE
1 - 2
EDGE
3 - 4
BUS CIRCUIT
5 - 6
AERIAL
J2
AUX
J3
MEMORY CARD Quick plug-in for MEMORY CARD connection for transmitters codes.
COURTESY
J4
LIGHT
MOTOR +
J5
ENCODER
IMPORTANT:
do not connect switching feeders or similar apparatus close to the control unit that may be
a source of disturbance.
4. LOGIC ADJUSTMENTS
TRIMMER
FR
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor to obstacles dimin-
ishes and therefore the thrust force increases; vice-versa, by rotating it counter-clockwise, the
sensitivity of the gearmotor to obstacles increases and therefore the thrust force diminishes.
Description
Power input 230 Vac
24 Vac board power supply input – Powered by transformer in relative com-
partment of T-SKY motor and protected by fuse (F 6,3A) on the 230 Vac po-
wer line.
Resistive sensitive edge input (DIP 10=ON); sensitive edge input – fixed
edge (DIP 10=OFF); 1 = Sensitive edge; 2= Common.
If neither the resistive sensitive edge nor the fixed edge are used, set DIP
10 to OFF and short circuit terminals 11 and 12;
Device input with BUS system.
433,92 MHz built-in RX aerial input; 5= Earth - 6= Signal;
Quick coupling for the connection of the T-WIFI and T-CONNECT devices
Quick coupling for the connection of the COURTESY LIGHT led
quick coupling for the connection of the MOTOR + ENCODER.
15
24 V AC - 50 Hz
8 A - 30 V DC
F 16 A
F 3,15 A
30 V DC
30 V DC
5V DC
-20 °C ÷ +55 °C

Publicidad

Tabla de contenido
loading

Tabla de contenido