FRAGMA
EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (stroke programming)
Programming sequence stopped due to intervention of a
safety device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Correct transmitter codes programming for opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes
saved)
Radio code deletion for opening
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Failure of a safety device or safety device engaged for too
long
Alarm from edge
Failed photocells auto-test alarm
Alarm - no limit switches reached or unlocked barrier
After having carried out the various connections and having supplied voltage, all the
LEDS are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The gate opens but does not close after the time set.
The gate does not close by activating the various START, RADIO and CLOSE buttons. Faulty safety edge contact. Faulty photocells contact => Fix or replace the faulty
By activating the START, OPEN or CLOSE button the barrier does not move.
The slowing phase is not performed.
Declaration of Conformity.
Vimar SpA declares that the equipment complies with Directives:
2014/53/EU (RED)
2014/30/EU (EMC)
2014/35/EU (LVD)
2006/42/CE (Machinery Directive)
The full text of the EU declaration of conformity is on the product sheet available at the following Internet address: www.vimar.com.
REACH (EU) Regulation no. 1907/2006 – Art.33.
The product may contain traces of lead.
28
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
10 seconds tone with 2 seconds
BUZZER STATUS
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
FAULT
FLASHER STATUS
Off
Off
Off
Off
Off
pause
FLASHER STATUS
Off
Off
Off
Off
1 Tone
Off
Off
Off
Off
Off
2 Tones
Off
FLASHER STATUS
Off
Off
1 Tone
Off
2 Tones
Off
Off
Off
Enabled for 1 minute
Off
5 Tones
Enabled for 1 minute
On the board there are resettable fuses which intervene in the event of a short
circuit, interrupting the output assigned to them.
In the event of troubleshooting, it is advisable to disconnect all the removable
connectors and insert them one at a time in order to more easily identify the
cause of the fault.
Check the integrity of fuse F1.
In case of interrupted fuse use only of adequate value
F1 = T 5A Fuse for motor protection
Check trimmers TORQUE, LOW SPEED OPEN and LOW SPEED CLOSE
adjustment.
Make sure that the TCA trimmer is activated with LED DL11 ON.
B.I.O. contact always on / green led on => check the status of the clock connected to
B.I.O. input.
Photocells Auto-test failed => check the connections between the control panel and
the photocells.
contact.
Photocells Auto-test failed => check the connections between the control panel and
the photocells.
START, OPEN or CLOSE command always active.
Check and replace any buttons or micro-switches of the selector switch.
Check LOW SPEED OPEN e LOW SPEED CLOSE trimmers adjustment.
EN
DL1 LED STATUS
Flashes on-off 250 ms
Flashes on-off 500 ms
On steady
DL12 LED STATUS
Flashes intermittently red/green
Flashes red for 10 seconds
Turns green once
Turns red once
Runs 6 green flashes
Runs 2 green flashes
LED STATUS AND SIGNAL OUTPUT
Led DL6 turns off
Led DL7-8 turns off
Led DL9 turns off
Led DL1 flashes on-off 250 ms
No led combined
No led combined
No leds matched
SOLUTION