INSTALLATION INSTRUCTIONS
C-WP-B-RDC Series
1L AND 3L
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This Product Must Be Installed In Accordance With The
Applicable Installation Code By A Person Familiar With
The Construction And Operation Of The Product And The
Hazards Involved.
Ce Produit Doit Être Installé Selon Le Code D'installation
Pertinent, Par Une Personne Qui Connaît Bien Le
Produit Et Son Fonctionnement Ainsi Que Les Risques
Inhérents.
3.
Suitable for wet locations.
Convient aux emplacements mouilles.
4.
Wall mount only.
Installation murale seulement
SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE
6L AND 10L
20L
http://lighting.cree.com/warranty
LPN00675X0001A1_A
Document:
Created By:
TMT
MOUNTING OVER RECESSED JUNCTION BOX
NOTE: Knockouts are provided for mounting over 3" octagonal or 4"
octagonal boxes.
1. Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from housing.
2. Drill out appropriate knockouts in back box for attachment to junction
box. Also drill knockout for wiring access.
NOTE: Fixture should not be exclusively supported by junction
box. Drill additional knockouts toward corners of fixture to provide
additional support. Do NOT drill within 1/4" (64 mm) from edges of
fixture.
3. Pull supply leads from junction box through wall of back box. Attach
back box to mounting surface using hardware (supplied by others)
appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber,
should be used around perimeter of back box to prevent water
leakage into fixture or junction box.
4. If the fixture is not CCT adjustable, proceed to Step 5.
For CCT adjustable fixtures, set the dip switch mounted to the back
box to the desired color temperature. Default setting is 4000K. Switch
can also be adjusted for 3000K or 5000K.
5. Make wiring connections per the Electrical Connections section.
6. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 1.
WALL MOUNTED WITH CONDUIT FEED
1. Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from housing.
2. Drill holes in four corners of back box to allow for attachment of
back box to mounting surface. Do NOT drill within 1/4" (64 mm)
from edges of fixture.
3. Attach back box to mounting surface using hardware (supplied by
others) appropriate for mounting surface.
NOTE: A high grade caulking material such as silicone rubber,
should be used around perimeter of back box to prevent water entry.
4. Remove appropriate threaded plugs on sides of fixture and route
electrical conduit to the holes desired. Feed the supply leads through
the conduit and into the back box.
NOTE: Use of teflon tape on the conduit threads will ensure a
watertight seal.
5. If the fixture is not CCT adjustable, proceed to Step 6.
For CCT adjustable fixtures, set the dip switch mounted to the back
box to the desired color temperature. Default setting is 4000K. Switch
can also be adjusted for 3000K or 5000K.
6. Make wiring connections per the Electrical Connections section.
7. Replace the lens assembly on hinges, re-connect quick-connect
wiring connectors, and swing lens into place. Re-tighten screws that
were loosened in Step 1.
|
1-800-236-6800
12-2-2020
Date

Publicidad

loading

Resumen de contenidos para C-LITE C-WP-B-RDC Serie

  • Página 1 LPN00675X0001A1_A 12-2-2020 Document: Date INSTALLATION INSTRUCTIONS Created By: C-WP-B-RDC Series MOUNTING OVER RECESSED JUNCTION BOX NOTE: Knockouts are provided for mounting over 3" octagonal or 4" octagonal boxes. 1. Remove lens assembly by loosening screws on side of frame. Swing lens assembly open,disconnect quick connect wiring connector(s) and lift lens assembly upward to remove from housing.
  • Página 2: Installation Instructions

    LPN00675X0001A1_A 12-2-2020 Document: Date INSTALLATION INSTRUCTIONS Created By: C-WP-B-RDC Series ELECTRICAL CONNECTIONS FCC NOTICE Fixture is equipped with universal volt driver 120-277V CAUTION: Changes or modifications not expressly approved could void (ie. 120V, 208V, 240V or 277V) your authority to use this equipment. PHASE TO NEUTRAL WIRING 120/277V 1.
  • Página 3: Medidas Importantes De Seguridad

    LPN00675X0001A1_A 12-2-2020 Documento: Fecha INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-B-RDC INSTALACIÓN SOBRE UNA CAJA DE CONEXIONES EMPOTRADA NOTA: Incluye orificios prepunzados para instalarse sobre cajas de conexiones octagonales de 3” (76 mm) u octagonales o cuadradas de 4” (101 mm). 1.
  • Página 4: Conexiones Eléctricas

    LPN00675X0001A1_A 12-2-2020 Documento: Fecha INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-B-RDC CONEXIONES ELÉCTRICAS AVISO DE LA FCC La luminaria está equipada con un controlador universal de voltaje PRECAUCIÓN: Los cambios o modificaciones que no se autoricen de 120 a 277 V expresamente podrían invalidar la garantía del equipo.
  • Página 5: Mesures De Sécurité Importantes

    LPN00675X0001A1_A 12-2-2020 Document : Date INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-B-RDC MONTAGE AU-DESSUS D'UNE BOÎTE DE DÉRIVATION ENCASTRÉE REMARQUE : Des débouchures sont prévues pour le montage sur des boîtes de dérivation octogonales de 7,6 cm (3 po) ou octogonales de 10,2 cm (4 po) .
  • Página 6: Raccordements Électriques

    LPN00675X0001A1_A 12-2-2020 Document : Date INSTRUCTIONS D’INSTALLATION Créé par : Série C-WP-B-RDC RACCORDEMENTS ÉLECTRIQUES AVIS DE LA FCC Le luminaire est équipé d’un système d’entraînement de tension MISE EN GARDE : Les changements ou modifications non expressé- universelle de 120 à 277 volts ment approuvés peuvent annuler votre droit à...