CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l'alimentation
avant l'installation.
2.
This luminaire must be installed in accordance with the
NEC or your local electrical code. If you are not familiar
with these codes and requirements, consult a qualified
electrician.
Ce produit doit être installé conformément à NEC ou
votre code électrique local. Si vous n'êtes pas familier
avec ces codes et ces exigences, veuillez contacter un
électricien qualifié.
3.
Downlight only.
Lumiere vers le bas seulement.
4. Suitable for wet locations.
Convient aux emplacements mouilles.
5.
Wall mount only.
Installation murale seulement.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
MOUNTING
NOTE: Do not recess. Also make sure fixture is weatherproof by
sealing all gaps and holes with weatherproof silicone sealant.
USING 1/2" PLUGS OR KNOCKOUTS IN THE BACK
1.
Remove lens assembly by loosening screws on side of frame.
Swing lens assembly open,disconnect quick connect wiring
connector(s) and lift lens assembly upward to remove from
housing.
2.
Drill appropriate knockouts from back of fixture for wiring access.
following:
http://creelighting.com/warranty
LPN00671X0001A1_A
Document:
Created By:
TMT
3.
Fixture is best mounted by drilling through back of fixture securing
it to the mounting surface using the appropriate mounting hardware
for the surface. Mounting hardware supplied by others. When
drilling holes, do not drill within 1/4" (6.4 mm) from edges of fixture,
also use caution when drilling near the power supply not to nick,
or leave metal chips behind. All unused holes must be plugged.
Waterproof silicone will ensure a tight seal.
4.
Complete the wiring to the power source and ground (refer to
electrical connection section).
5.
Replace lens assembly, re-connect wiring connectors, and swing
lens assembly into place. Tighten screws that were loosened in
Step 1.
USING 1/2" PLUGS ON THE SIDE
1.
Remove lens assembly by loosening screws on side of frame.
Swing refractor open, disconnect quick connect wiring connector(s)
and lift lens assembly upward to remove from housing.
2.
Remove 1/2" plug from direction you intend to feed conduit.
3.
Fixture is best mounted by drilling through back of fixture securing
it to the mounting surface using the appropriate mounting hardware
for the surface. Mounting hardware supplied by others. When
drilling holes, do not drill within 1/4" (6.4 mm) from edges of fixture,
also use caution when drilling near the power supply not to nick,
or leave metal chips behind. All unused holes must be plugged.
Waterproof silicone will ensure a tight seal.
4.
Feed conduit to the desired hole and complete the wiring to the
power source and ground (refer to electrical connection section).
5.
Replace lens assembly, re-connect connectors, and swing lens
assembly into place. Tighten screws that were loosened in Step 1.
ELECTRICAL CONNECTIONS
Fixture is equipped with universal volt driver 120-277V
(ie. 120V, 208V, 240V or 277V)
PHASE TO NEUTRAL WIRING 120/277V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply common to fixture neutral (white) lead.
3. Connect supply Vin to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
PHASE TO PHASE WIRING 208/240V
1. Connect supply ground to fixture ground (green) lead.
2. Connect supply L1 (Hot) to fixture neutral (white) lead.
3. Connect supply L2 (Hot) to fixture hot (black) lead.
Tuck all wires carefully into wiring chamber ensuring that no wires
are pinched.
DIMMING
1. If 0/1-10V Dimming is used, connect the violet lead to the
supply positive dimming lead. For dimming, use Class 1 wir-
ing methods only. If dimming is not being used ensure to cap
off the violet lead.
2. If 0/1-10V Dimming is used, connect the grey or pink lead to
the supply negative dimming lead. For dimming, use Class 1
wiring methods only. If dimming is not being used ensure to
cap off the grey or pink lead.
|
866.924.3645
7-28-2021
Date

Publicidad

loading

Resumen de contenidos para C-LITE C-WP-D-TR Serie

  • Página 1 LPN00671X0001A1_A 7-28-2021 Document: Date INSTALLATION INSTRUCTIONS Created By: C-WP-D-TR Series Fixture is best mounted by drilling through back of fixture securing it to the mounting surface using the appropriate mounting hardware for the surface. Mounting hardware supplied by others. When drilling holes, do not drill within 1/4”...
  • Página 2: Installation Instructions

    LPN00671X0001A1_A 7-28-2021 Document: Date INSTALLATION INSTRUCTIONS Created By: C-WP-D-TR Series FCC NOTICE CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Página 3: Medidas De Seguridad Importantes

    Documento: LPN00671X0001A1_A Fecha 7-28-2021 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-D-TR La luminaria se monta mejor al perforar desde la parte posterior, y fi jarla en la superfi cie de montaje usando los accesorios de montaje adecuados para la superfi cie. Accesorios de montaje de otros proveedores.
  • Página 4 Documento: LPN00671X0001A1_A Fecha 7-28-2021 INSTRUCCIONES DE INSTALACIÓN Creado por: Serie C-WP-D-TR AVISO DE LA FCC PRECAUCIÓN: Los cambios o modifi caciones que no se autoricen expresamente podrían invalidar su autoridad para usar este equipo. Este dispositivo cumple con la Sección 15 de las normativas de la FCC.
  • Página 5: Mesures De Sécurité Importantes

    Document : LPN00671X0001A1_A Date 7-28-2021 NOTICE D’INSTALLATION Créé par : Série C-WP-D-TR L’appareil sera mieux fi xé en perçant sa face arrière et en le fi xant à la surface de fi xation à l’aide de la quincaillerie de montage appropriée. Matériel de montage fourni par des tiers.
  • Página 6 Document : LPN00671X0001A1_A Date 7-28-2021 NOTICE D’INSTALLATION Créé par : Série C-WP-D-TR AVIS DE LA FCC MISE EN GARDE : Les changements ou modifi cations non expressément approuvés peuvent annuler votre droit à utiliser cet équipement. Cet appareil est conforme avec la Partie 15 des Règlements de la FCC.