7. SCHEDULE
The schedule consists of 4 periods per day which represents a typical
weekday. You can program the thermostat to skip the periods that do
not apply to your situation. For example, you can skip periods 2 and 3
for the weekend.
Period
The Comfort ( ) temperature is used in periods 1 and 3 and the
Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically
changes from Comfort setting ( ) to Economy setting ( ).
You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.
Period Setting
MO
TU
6:00
6:00
AM
AM
8:00
8:00
AM
AM
6:00
6:00
PM
PM
10:00
10:00
PM
PM
To modify the schedule:
1. Press Pgm to access the programming mode. Period 1 is
selected.
2. Press Day to select the day to program (hold for 3 seconds to
select the entire week).
3. Press Hour and Min to set the start time of the selected period,
or press Clear if you want to skip the period (--:-- is displayed).
4. Press Pgm to select another period, or press Day to select
another day. Then repeat step 3.
5. Press Mode to exit the programming mode.
NOTE:
If no button is pressed for 60 seconds, the thermostat will
automatically exit the programming mode.

8. POWER OUTAGE

During a power outage, LP (Low Power) appears for the first minute.
Then the screen becomes blank. The settings are stored in memory.
After initial installation, product must be connected to power for a
minimum of two hours to enable the power outage feature. However,
if the power failure exceeds 4 hours, the thermostat's clock must be
re-adjusted and, if you are using the automatic Daylight Savings
Time changeover function, it must be re-enabled. When power
returns, the thermostat will return to the mode of operation active
prior to the power failure.
Description
Setting
Wake
Leave
Return
Sleep
WE
TH
FR
SA
6:00
6:00
6:00
6:00
AM
AM
AM
AM
8:00
8:00
8:00
--:--
AM
AM
AM
6:00
6:00
6:00
--:--
PM
PM
PM
10:00
10:00
10:00
10:00
PM
PM
PM
PM

9. TROUBLESHOOTING

PROBLEM
Thermostat is hot.
LO is displayed.
HI is displayed.
Wrong temperature is
displayed.
Wrong time is displayed.
Temperature does not
change according to the
programmed schedule.
LP appears on the screen or
the screen is blank despite
there is no power outage.
SU
6:00
AM
Display looks faded when
heating is activated.
--:--
--:--
The settings cannot be
changed.
10:00
E1/E2 is displayed
PM

10. TECHNICAL SPECIFICATIONS

Power: 120/240 VAC, 60 Hz
Minimum load:
2 A (resistive only)
250 W @ 120 VAC
500 W @ 240 VAC
Maximum load:
16.7 A (resistive only)
2000 W @ 120 VAC
4000 W @ 240 VAC
Display range: 0°C to 60°C (32°F to 140°F)
Display resolution: 0.5°C (1°F)
Setpoint range: 5°C to 30°C (40°F to 86°F)
Setpoint interval: 0.5°C (1°F)
Storage: -20°C to 50°C (-4°F to 120°F)
Approval: c UL us
ICES-003 Class B Notice
This Class B digital apparatus complies with Canadian ICES-003.
3
TH106 PROGRAMMABLE THERMOSTAT
SOLUTIONS
Under normal operation, the
thermostat housing can reach a
temperature between 35°C (95°F) and
40°C (104°F).
The measured temperature is below
the display range. Heating is
activated.
The measured temperature is above
the display range.
The thermostat is exposed to air draft.
Eliminate the draft. The sticker on the
thermostat's screen has not been
removed.
The thermostat was without power for
more than 4 hours.
Check that the thermostat is in
Automatic mode. Check the schedule
and clock settings.
The thermal circuit breaker in the
heater is opened. This can happen if
the heater is obstructed by furniture or
curtain and has overheated, or if the
thermal circuit breaker is defective.
The heating system is less than the
required minimum load. This
thermostat cannot be used below that
rating.
The settings are locked (see section
3).
The thermostat performance is
reduced due to a sensor error. Please
contact technical support for more
information.
Energy Verified
273699
Only
69-2544EFS—07