Conversion from LP Gas to
Natural Gas
Installation of the regulator
1.
Turn off the main gas supply valve.
2.
Disconnect 20 lb LP gas fuel tank (if present).
3.
Turn off all burner control valves.
4.
Remove the 20 lb LP gas fuel tank (if present) from the
grill cart.
5.
Use an adjustable wrench to remove the LP regulator
from the manifold.
6.
Use an adjustable wrench to install the Natural gas
regulator hose to the manifold and secure. Attach the
Natural gas regulator to the side panel inside the grill cart
with the two screws that are preassembled on the
regulator.
Make Gas Connection
1.Before making any connections, check to ensure the natural gas
inlet pressure falls between the allowable range of 7" W.C. / 0.25
psi and 14" W.C. / 0.5 psi. If the NG inlet pressure does not fall
within this range, contact your local gas supplier.
2.A combination of pipe fittings must be used to connect the grill to
the existing gas line.
•The 10 ft (3.0 m) PVC flexible gas supply hose design certified by
CSA must be used.
•Pipe-joint compounds suitable for use with Natural gas must be
used. Do not use Teflon®+ tape.
•There must be a certified manual shut-off valve in the gas supply
line near the grill for easy access.
3.Connect the brass connector on one end of the 10 ft (3.0 m) PVC
flexible gas supply hose to the Natural gas pressure regulator
4..
4.Connect the quick connector on the other end of the 10 ft (3.0 m)
PVC flexible gas supply hose to the rigid Natural gas supply pipe.
† ®TEFLON is a registered trademark of Chemours.
27