Operating
radius (r)
Mode
Fixed
Steel
2m
*Interfering frequencies (bandwidth <20Hz) are filtered out.
8.2. Test input (Fig. 5) (terminal 4)
The GMXS1 internal test transmitter (Fig. 6) is activated via the test input.
If the detector is functioning correctly, it will trigger an alarm (trigger time
<3 s). Factory setting: Active Low
8.3. Alarm relay polarity (Fig. 1, item F)
The setting is activated after 3 seconds.
Alarm relay
Normally Open
9.
Commissioning
1.
Apply the supply voltage.
2.
Leave the detector for 30 seconds.
The detector is now operational.
3.
Verify that the correct radius has been selected by the DIP switches.
Check for interference using a multimeter (Ri ≥ 20 kΩ) at terminal 1 (0 V)
and at the test point (Fig. 1, item D) to monitor for the analogue integration
signal:
Quiescent level
Integration start
Alarm threshold (w/o load)
9.1. Functional checks
Functional checks can be performed as follows:
With the cover removed, scratch the metal case of the detector with a
screwdriver to trigger an alarm.
Apply the required input to terminal 4 to activate the GMXS1 internal
test transmitter, if provided.
Apply the required input to activate the GMXS5 auxilary test
transmitter, if provided.
Simulate an attack on the protected space.
Carefully replace the cover and secure it in place.
10. Service
The function of the detector and its mounting should be checked at least
once a year, as follows:
Functionally test the detector as detailed in section 9.1.
Verify the settings of the detector by the DIP switch options.
Check the mounting of the detector to ensure that the detector is
securely attached.
Check that there is a direct connection between the detector and the
mounting surface. Paint, varnish, dirt, silicone or similar materials will
impede the acoustics.
Refer to local approvals for guidance on this matter.
11. Technical data
Dimensions
Supply voltage (nom. 12 V DC)
Current consumption (8 to 16 V 0DC)
Alarm condition
Alarm output, terminals 14+15:
Semiconductor relay
Contact load
Series resistance
Alarm holding time
Sabotage surveillance, terminals 10+11:
Microswitch, cover and floor Opens on sabotage
A6V10221656_d
Fixed
Fixed
Fixed
1m filter*
1.5m
1m
Normally Closed
0 V
1 V
3 V
89mm x 89mm x 23mm
Vcc = 8 to 16 V DC
Ityp. = 2.5 to 3.5 mA
Imax. = 5 mA
Opens on alarm + low voltage
30 V DC/100 mA, ohmic load
<45 Ω
2.5 s
Contact load
Test input, terminal 4
Operating temperature
Storage temperature
Air humidity (EN 60721), non-
condensing
Approvals
12. Ordering Information
GM710 Seismic detector
GMXP0 Mounting plate – GM7xx
GMXS1 Internal test transmitter –
GM7xx
GMXS5 External test transmitter –
GM7xx
GMXP3 Lock protection – GM7xx
GMXP3Z Lock protection – GM7xx
GMAS6 Movable mounting kit –
GM7xx
GMXC2 Connection sleeve (16mm) –
GM7xx
de
1.
EG-Konformitätserklärung
Hiermit erklärt Vanderbilt International (IRL) Ltd, dass dieser Gerätetyp
den Anforderungen aller relevanten EU-Richtlinien für die CE-
Kennzeichnung entspricht. Ab dem 20.04.2016 entspricht er der
Richtlinie 2014/30/EU (Richtlinie über elektromagnetische Verträglichkeit).
Der vollständige Text der EU-Konformitätserklärung steht unter folgender
Internetadresse zur Verfügung:
http://pcd.vanderbiltindustries.com/doc/Seismic.
2.
Anwendung
Der Körperschallmelder GM710 erkennt zuverlässig Aufbruchsversuche
bei Safes, Geldautomaten, Fahrscheinautomaten, Verkaufsautomaten,
Nachttresoren, Stahlkammern und Tresorräumen aus Stahl. Die
intelligente Signalverarbeitung erlaubt eine individuelle Einstellung der
Detektionsempfindlichkeit und somit eine hohe Sicherheit gegen
Falschalarm. Der Sabotageschutz für die Melderabdeckung (Abb. 1,
Element A) erkennt ein Öffnen des Melders. Der Sabotageschutz auf der
Rückseite des Melders erkennt ein gewaltsames Entfernen.
Die Montage, Programmierung und Inbetriebnahme müssen
durch Fachpersonen erfolgen.
Zusätzliche Zulassungsanforderungen sind im Anhang am
Ende dieses Dokuments enthalten.
3.
Inhalt
1 Körperschallmelder GM710
1 Bohrschablone GM7xx
3 Kabelbinder
4.
Wirkbereich
Die vom Melder überwachte Fläche wird als Wirkbereich bezeichnet.
Dieser breitet sich kreisförmig vom Melder mit einem Wirkradius (r) aus.
Melderwirkung
4
30 V DC/100 mA
Low <1.5 V/High >3.5 V DC
-40 ºC to +70 ºC
-40 ºC to +70 ºC
<95%
See the type plate inside the
detector cover
V54534-F106-A100
VBPZ:2772730001
VBPZ:4202370001
VBPZ:5627000001
VBPZ:3470190001
VBPZ:5712410001
VBPZ:4886060001
VBPZ:5021840001