In models 574CL, 575CL there is no U-
latch and the adjustment is done by
turning the adjustment sleeve to the
desired %.
In models 571 Green there is no
possibility to adjust the dosing percentage
it is predeterment by the injector model
(see page 3)
Rinsing and Cleaning the unit
After pumping
• Rinse the unit by pumping clean water from the additives
• Wash the external surface of the unit with clean water.
Air-release Valve
In models: 571 Green, 570(CW/CL/PVDF), 572(CW/CL/PVDF),
574CL, 576IN, 578IN.
After initial operation of the MixRite, apply pressure to the cap (the
air release valve) for several seconds to open valve that allows
trapped air to escape. This air release is accompanied by a slight
loss of water. Release the pressure on the cap to close the valve.
I-870
Rev F - 36742
DO NOT REMOVE THE LOWER U-LATCH !!!
(For maintenance purpose only)
container.
Warning: During pumping, ensure that the additive
container is not completely empty.
Press to release air
U-latch
To decrease
To increase
Air is released with a
small amount of
water
Page 7 of 30