Removing air conditioner from window
Turn air conditioner off, and disconnect power cord.
Remove sash seal from between windows and unscrew safety sash lock.
Remove screws installed through frame and frame lock.
Keeping a firm grip on the air conditioner, raise sash and carefully remove.
Be careful not to spill any remaining water while lifting unit from window. Store parts
with air conditioner.
Be sure to drain excess water from unit before storing.

Displays

Digital display shows the temperature and
the Auto timer settings. Fan Only mode
shows the room temperature. Temperatures
displayed in
F.
O
Error Codes:
AS - Room Temperature sensor error. Unplug
the unit and wait 3 minutes before you plug
it back in. Note: in Fan Only mode, it will
display "LO" or "HI."
• - Evaporator temperature sensor error.
Unplug the unit and wait 3 minutes before
you plug it back in. Note: "•" is displayed
in the unit controls (Fig. 12).