CHECk oPEratIoN aNd adjuStMENt
Note: When first turned on or when switching modes wait 30
seconds.
Note: When using test mode to check operation in the day time, set
the DETECT control switch to DAY/NIGHT.
1. Check Operation. Set the ON-TIME control to TEST mode. Walk in
front of sensor unit. The LED indicator light should flash when motion
is detected (see illustration, page , for location of LED light).
2. Adjust Sensor. Turn the RANGE control to the mid position and
ON-TIME control to the TEST position. Walk through coverage
area noting where you are when the LED begins to flash.
3. Adjust RANGE Control. To increase sensitivity, turn the RANGE
control toward MAX. To decrease sensitivity, turn the RANGE
control toward MIN. Note: If the RANGE is set too high, false
triggering may result in some environments.
. Set ON-TIME Control. Determine the amount of time you want
the connected device to stay on after motion is detected (1 or
5 minutes). Slide the ON-TIME control to the corresponding
setting.
5. Make adjustments and snap sensor unit onto base.
IMPORTANT: Avoid Aiming Control At:
• Objects that change temperature rapidly, such as heating vents,
fans, and air conditioners. These air sources could cause false
triggering.
• Areas where pets or traffic may trigger the control.
• Nearby large, light colored objects reflecting light may trigger the
shut-off feature. Do not point other lights at the sensor.
598-1271-01
Maximum Range
Maximum Coverage Angle
Solar Motion Sensor Coverage Area
Motion
Sensor
Least Sensitive
The detector is most sensitive to motion across its field of view.
Solar Motion Sensor Sensitivity
5
70 ft.
(2. m)
360°
Motion
Sensor
Most Sensitive