Yellow Wires Utilization; Erase Memory - A.E.B. AEB215 Manual De Uso

Tester palmar
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

VEHICLE CONFIGURATION
YELLOW WIRES UTILIZATION (Fig. 38)
The two YELLOW wires of the LEONARDO E.C.U. are connected to an
internal RELAY and they can be used for two different functions.
This option allows the selection of either:
DISCONNECT INJECTORS
Enter this option when the two YELLOW wires are used to open a
circuit during the GAS operation, and restore it during PETROL
operation (ie. fuel injection or indicator lamp).
DISCONNECT (CLEAR) MEMORY (Fig. 39)
Enter this option when the two YELLOW wires are used to open circuit
the memory wire of an E.C.U..
When this mode is selected, the memory feed of the E.C.U. is open
circuited by the two YELLOW wires a few seconds after the ignition
key has been turned off (this is to allow the engagement of possible
anti-theft devices). The circuit is restored after a few minutes.
ERASE MEMORY (Fig. 40)
When the "OK" key is pressed on this function, all previously entered
parameters are erased from memory and the LEONARDO is brought
back to the original base configuration.
Press the "OK" key; the display will show the verbiage as in Fig. 41.
Confirm by pressing the "OK" key once again.
If this function has been selected in error, press the "ESC" key in
order to go back to the "MAIN MENU" without changing any parameter.
52 - 188
LEONARDO
YELLOW WIRES
UTILIZATION
DISCONNECT
INJECTORS
Fig. 38
YELLOW WIRE
UTILIZATION
DISCONNECT
(CLEAR) MEMORY
Fig. 39

ERASE MEMORY

Fig. 40
ERASE MEMORY
PRESS [OK] TO
CONFIRM
Fig. 41
Is215-2 Rev. 110105-2

Publicidad

Tabla de contenido
loading

Tabla de contenido