Safety Instructions: Zone; Temperature Tables; Connection Data - Pepperl+Fuchs Pulscon LTC51 Manual De Instrucciones

Tabla de contenido

Publicidad

Pulscon LTC51
SI01127O-C
Safety instructions:
Zone 0

Temperature tables

Connection data

Service interface
U
= 7.3 V
i
effective inner inductance L
= negligible
i
effective inner capacitance C
= negligible
i
U
= 7.3 V
o
I
= 100 mA
o
P
= 160 mW
o
L
(mH) =
5.00
2.00
o
C
(µF) =
0.73
1.20
o
• In the event of potentially explosive vapor/air mixtures, only operate the device under
atmospheric conditions.
– Temperature: -20 °C ... +60 °C
– Pressure: 80 kPa ... 110 kPa (0,8 bar ... 1,1 bar)
– Air with normal oxygen content, usually 21 % (V/V)
• If no potentially explosive mixtures are present, or if additional protective measures have been
taken according to EN 1127-1, the device may also be operated under non-atmospheric
conditions in accordance with the manufacturer's specifications.
• Associated devices with galvanic isolation between the intrinsically safe and non-intrinsically
safe circuits are preferred.
• If there is a risk of dangerous potential differences within Zone 0 (e. g. through the occurrence of
atmospheric electricity), implement suitable measures for intrinsically safe circuits in Zone 0
(e. g. in accordance with the requirements of IEC/EN 60079-14).
see page 23
Basic specification, option "Approval" = E2, ID
Ex ic
• Power supply and signal circuit with protection type: intrinsic safety Ex ic IIC or IIB.
Basic specification, Option "Electrical output" = ID (TRC [02])
Terminal 1 (+), 2 (–)
Power supply:
U
= 35 V
i
I
= not applicable (current-controlled circuit)
i
P
= not applicable
i
effective inner inductance L
= 0 µH
i
effective inner capacitance C
= 5 nF
i
Service interface (CDI)
Taking the following values into consideration, the device can be connected to the certified service
tool or a similar interface:
1.00
0.50
0.20
1.60
2.00
2.60
Terminal 3 (+), 4 (–)
Switch output (PFS):
U
= 35 V
i
I
= not applicable (current-controlled circuit)
i
P
= 1 W
i
effective inner inductance L
effective inner capacitance C
effective inner capacitance to ground C
0.10
0.05
0.02
3.20
4.00
5.50
= 0 µH
i
= 3 nF
i
= 5.28 nF
i
0.01
0.005
0.002
0.001
7.30
10.00
12.70
12.70
EN
15

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido