4.1.2
L2 led - Wire speed.
In Parameter selection internal mode, D1 shows the
welding wire speed set in the recalled program.
The value may be changed using M1.
This change affects the value of the set voltage, which may
be seen on D2 with L4 lit.
In the other operating modes, D1 shows the welding wire
speed set in the recalled program.
4.1.3
L3 led - Current.
In Parameter selection internal mode, D1 shows the pre-
set welding current of the recalled program.
The value may be changed using M1.
This change affects the value of the set voltage, which may
be seen on D2 with L4 lit.
In Manual mode, D1 reads 0 (zero).
Only after a welding in combination with L8 lit does it
indicate the actual welding current measured.
In the other operating modes, D1 shows the welding current
pre-set in the selected program or, if in combination with
L8 lit, the actual welding voltage is measured.
3.300.559/C
4.2
T2 key.
Always operative.
Each time this key is pressed, it calls up the measure you
wish to show on D2.
The selected measure is indicated by the lighting of the
corresponding led.
4.2.1
L4 led - Voltage.
In Parameter selection internal mode, D2 shows the pre-
set welding voltage of the recalled program.
The value may be changed using M2.
In Manual mode, D2 shows the pre-set welding voltage
or, if in combination with L8 lit, the actual welding volt-
age measured.
In the other operating modes, D2 shows the welding voltage
pre-set in the recalled program or, if in combination with
L4 lit, the actual welding voltage is measured.
Moreover (excluded in Job mode) if M2 is turned, D2
temporarily displays (5 s) the "Arc Length" correction in-
dicated by L5 lit.