READ ALL THE INSTRUCTIONS
TRIM COMPATIBILITY
USE ONLY WITH THE FOLLOWING MODELS:
LiteChoice: 9Y6WHWH-4Cxx, 1F6WHWH-2Cxx, 9Y6WHWH-2Cxx,
1G6SCWH-29xx, 1D6WHWH-2Cxx
Commercial Electric: CER6730, CER6041, CER6741, CER6742,
CER6732DB, CER6732DS
EnviroLite: EVL6730, EVL6041, EVL6741, EVL6742, EVL6732DB,
EVL6732DS
TOOLS & MATERIALS REQUIRED
Ladder, BX or NM Cable, BX Cable Connectors (if necessary),
Keyhole Saw, Flathead Screwdriver, Hammer, Insulated Pliers,
Pencil, UL Listed Electrical Tape.
Before assembling your lighting fixture, refer to the section titled
ELECTRICAL CONNECTIONS.
electrical wiring experience, refer to a do-it-yourself wiring handbook
or have your fixture installed by a qualified licensed electrician.
NOTE: This fixture is an IC type fixture. It may come in direct
contact with thermal insulation. It can be completely covered
by thermal insulation, as shown below. In addition, any part of
the fixture may come in direct contact with any combustible
material, such as a ceiling joist or floor board. (FIG. 1)
NOTE: Insulation
may completely
cover fixture.
Insulation
BEFORE YOU BEGIN
1. To ensure the success of the installation, be sure to read these
instructions
and review the
beginning.
2. All electrical connections must be in accordance with local code,
ordinances.
If you are unfamiliar with methods of installing
electrical wiring, secure the services of a qualified licensed
electrician.
3. Before starting the installation, disconnect electricity at the circuit
breaker or the fuse box. Disconnecting power by using the wall
switch is not sufficient to prevent electrical shock.
4. Check if the power source is suitable for the added electrical
load. Power should be supplied by a 110/120 volt, 60 Hz single
circuit. A standard 120 volt, 15 amp branch circuit is designed to
carry a maximum load of 1800 watts. We recommend that the
total wattage of all the lights and appliances on that circuit, not
exceed 80% or 1440 watts, of the maximum electrical capacity.
6" LED NEW CONTRUCTION AIRTIGHT
IC-RECESSED HOUSING INSTALLATION
INSTRUCTIONS – MODEL EVR6SLICAT
CAUTION
If you feel you do not have
Fixture
Joist
diagrams
thoroughly
ALL RIGHTS RESERVED. COPYRIGHT Envirolite 2016
5.
This product has a special feature, which secures the NM
(Romex) cable to the junction box, in lieu of a cable connector.
This feature will not work with BX (armored) cable. For BX
cable, cable connectors need to be purchased separately. See
the "ELECTRICAL CONNECTIONS" section.
6.
This is a new-construction fixture. This new-construction
fixture can be installed in applications where the ceiling surface
has yet to be installed and the ceiling joists are exposed, such
as when a home is under new construction. If a ceiling surface
already exists and there is no access above the ceiling surface,
do not use this fixture. A remodel fixture is recommended,
instead. This fixture may also be installed onto a drop ceiling,
where there is a standard T-bar grid in place.
Check
the
1 - Housing/Hanger Bar Assembly, 1 - Cardboard Circular Template,
3 - "Quick-Connect" Wire Connectors (inside junction box)
PREPARING AND MOUNTING THE FIXTURE
HANGER BAR PREPARATION
The hanger bars are designed for joists that are spaced 16" to 26"
(center to center) apart. If the joists are less than 16" apart, the
hanger bars must be shortened to accommodate the narrower
space. To shorten them:
1. Remove the hanger bars from the plaster frame.
require opening the guides of the plaster frame using pliers.
FIG. 1
2. Spread the bars as wide as possible. (FIG. 2)
3. For each hanger bar, bend the "male" bar, back and forth at the
crease from the center until it splits. Bend the "female" bar,
st
1
back and forth, at the 1st notch from the center until it splits.
(FIG. 2)
Crease –
st
1
Bend Here
before
4. Slide the "male" and "female" bars together and determine if the
hanger bar has been shortened enough. If not, separate the
"male" and "female" bars and break off additional material at the
next crease and notch.
proper length is achieved. Do not break off any more material
than necessary.
5. Once proper length is achieved, separate the "male" and
"female" bars. Slide the "female" bars into the guides of the
plaster frame. Slide the "male" bars into the "female" bars.
QUESTIONS? CALL TOLL
FREE
UNPACK THE FIXTURE
contents
of
the
box.
Notch –
st
1
Bend Here
"Male" Bar
Continue to break off material until
1-855-573-6156
You
should
have:
This may
"Female" Bar
FIG. 2