OPERATING AND MAINTENANCE MANUAL
SUBMERSIBLE SEWAGE PUMP
Thanks for choosing our product. Please read the manual carefully before operation.
1. WARNINGS!
• Before operation, make sure that the electric pump is properly grounded.
• Do not touch the electric pump while it is running.
• Do not run the electric pump without water.
Submersible Sewage Pumps (hereinafter referred to as simply "electric pump") consist of water
pump seal and motor. The electric pumps adopt single phase or three-phase asynchronous motor.
The motor are fitted at the upper part of electric pump, whereas the water pump fitted at the lower
part of it. Submersible pumps adopt flow passage impeller with volute casing type, possessed
excellent anti-jam and strong wearability, suitable for transport of big solid granules. Being assem-
bled stainless steel pump body and shaft, these products look artistic and use in practice. Single
or double mechanical seal is used between water pump and motor, and O-ring is applied among
all the static joints.
These serial sewage submersible pumps are widely apply to industry, agriculture, mining, cons-
truction and urban environmental protection. As ideal equipment , they are used for pumping
mud, mortar, waste water, sewage water, excrement and urine, such as solid granules short fiber,
wastepaper and mud as well as sand, farm drainage and irrigation, river and pond dredging except
for flammable media and blast environment.
If at any time in the future you should need to dispose of this product or
any part of this product, please note that waste electrical products, bat-
teries or cables should not be disposed of with household waste. Please
recycle where facilities exist, please check with your local authority for
recycling advice.
The abandonment or uncontrolled disposal of waste can cause harm
to environment and human health. So, by recycling this product in a res-
ponsible manner, you contribute to the preservation of natural resources
and to the protection of human health.

2. CONDITIONS FOR USE

The pump will wor k normally and continuously in the following conditions:
1. Maximum medium temperature: + 40 ºC
2. PH of applicable media: the stainless steel pump is 2 ~ 13, the cast iron pump is 4 ~ 10.
3. Medium density: 1,2 10³kg / m³.
4. Maximum volumetric of medium solid: 2% except the pumps with cutting feature. The electric
pump performances must meet the technical parameter marked on the name plate.
5. Maximum submersible depth: 5 m.
www.proindecsa.com / proindecsa@proindecsa.com