Broken Hose (Optional); Menu Utility - VERDER VP2-HT CL Manual De Instalacion Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

If your pump has not included the enable option then it will not be possible to access the "Enable" submenu and the
flashing message "DEA" will appear:

BROKEN HOSE (OPTIONAL)

What is that?
It is a sensor that detects if the peristaltic tube is torn and leaves the chemical to
come out. When the broken hose alarm starts, it stops the dosage and the green led
flashes and the display shows "broken hose" .
Before any intervention, disconnect the pump from the mains supply!
During the operation always use the personal protections
recommended by the warnings of use of the dosed chemical. For
example, use gloves, apron, glasses, etc ...
The peristaltic hose must therefore be changed. The sensor area inside the pump
housing must also be rinsed and carefully dried. See the explanatory image on the side.
To esc from this alarm push the ESC button.
Once the operation has been carried out safely, the pump can be restarted.
NB: IF THE PUMP IS SWITCHED OFF DURING THE BROKEN HOSE ALARM, WHEN IT WILL BE SWITCHED ON
AGAIN IT WILL REMEMBER THE PREVIOUS ALARM. TO EXIT FROM THE BROKEN HOSE ALARM SHORTLY
PUSH THE ESC BUTTON.
In the case that your pump has the "Broken Hose" option, you can choose to activate this input or not.
If your pump has not included the Broken Hose option then it will not be possible to access the "Brok.Hose" submenu and
the flashing message "DEA" will appear:

MENU UTILITY

The Utility menu allows you to program the Delay On, the overdose TAL alarm, allows you to choose the type of flow
sensor used (Normally Open or Normally Closed), to restore the factory programming of the parameters and the factory
probe calibration.
IMPORTANT NOTE:
The input for the flow sensor is an option. If in your pump is not present you will not be able to access the
submenu and the display will write:
Rev 1.1
In the Set up menu, select "Enable" by the cursor and
press ENTER.
Use the ▼ ▲ buttons to select whether to enable ("active")
or disable (deactive) this input and press ENTER.
If you want to esc programming and return to
measurement, press ESC for 3 seconds.
In the Set up menu, select "Brok.Hose" by the cursor and
press ENTER.
Use the ▼ ▲ buttons to select whether to enable ("active")
or disable (deactivate) this input and press ENTER.
If you want to esc programming and return to
measurement, press ESC for 3 seconds
Cod. 00.009.127
27

Publicidad

Tabla de contenido
loading

Tabla de contenido