After Sale Service - SATA 400 Instrucciones De Servicio

Ocultar thumbs Ver también para 400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 87
Operating instructions SATA filter 400
Malfunction
Drain valve blows
permanently (never
disassemble the drain
valve itself, risk of
damage)
12. Disposal
The oil and condensate free filter has to be disposed of as recycable
waste. Please observe local regulations!

13. After Sale Service

Accessories, spare parts and technical support may be obtained from
your SATA dealer.
14. Warranty / Liability
The SATA General Conditions of Sale and Delivery and further contrac-
tual agreements, if applicable, as well as the valid legislation at the time
apply.
SATA cannot be held responsible especially in the following
cases:
• When the operating instructions are disregarded.
• When the product is used in other than the intended ways of usage.
• When untrained staff are employed.
• When no personal protection equipment is worn.
• When no original accessories and spare parts are used.
• When the product is manipulated, tampered with or technically modi-
fied.
• In case of normal wear and tear.
• In case when the product has been exposed to untypical shockloads
and impacts during usage.
Cause
Filter is not installed
vertically
Brass piece not visible
on the bottom
Floater stuck on the
drain valve
Damaged drain valve
Internal filter pressure
< 1 bar
Corrective action
Install filter vertically
Pressurise filter and
pull brass piece down-
wards
Remove drain valve
and clean or exchange
it
Exchange drain valve
Art. No. 15511
Increase inlet pressure
EN