8/28 Bosch Rexroth AG | Electric Drives and Controls
1

Technical Data

Designation
Order number
Admissible ambient temperature
Admissible relative humidity when in operation
Admissible storage temperature
Admissible relative storage humidity
System of protection
Dimensions board (w x h x d)
Weight
Table 1:
Subject to alteration
2

Intended Use

The interface module SMibs is intended for
installation in the tightening control system
SE302 or communication unit KE300. With
this interface, a tightening system is con-
trolled.
The SMibs interface module is an
I
B
S-slave. It enables the tightening
NTER
US-
system 300 to be connected to the I
B
-S field bus.
US
Via this connection, the tightening system
can be controlled by the superior control sys-
tem, e.g. PLC control. The SMibs is inserted
into one of the open card slots on the KE300
communications unit. The module takes up
an address size of max 160 I/O points
(20 Bytes) on the field bus. Depending on
the tightening system requirements, this ad-
dress size is adjustable from 16 I/O points
(2 Bytes) up to 160 I/O points (20 Bytes).
Adjustments are made in steps of 2 Bytes us-
ing the BS300 operating system. Via the
pure I/O coupling, the SMibs offers the pos-
sibility to transfer tightening result data
through the PCP data channel (Peripherals
Communication Protocol) to the bus master.
SMibs
0 608 830 164
0 up to 55 °C with ventilator
20 - 90 % non-condensing
– 20 °C up to 70 °C
20 - 95 %
IP 20 (~ NEMA 1) when installed
24 mm x 81 mm x 207 mm
0.05 kg
NTER-
SMibs | 3 609 929 723/1.2