NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING
POINTS WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
Before any opera on on the float remember to disconnect the power supply from the main power.
Ÿ
Check that the maximum motor power does not exceed the float's electrical values.
Ÿ
In case of cable damage by the final user or installer, the float must be replaced.
Ÿ
Do not make any joint on the cable of the float switch, as immersion of such joints could cause short circuits or
Ÿ
electrical shocks.
USE:
Unlike normal floats, the level regulator is used in pairs of two of the same type to regulate water levels to a certain
height: one regulates the minimum level and the other regulates the maximum level. A third and fourth regulator
can also be used for minimum and maximum alarm respec vely. To avoid damaging the cable, we recommend the
Fixing Kit (Fig.1)
The tank fills
TECHNICAL FEATURES:
AC: Max 10A (250V) resis ve load - 8A (250V) motor load
Ÿ
Min 1200mW (12V/100mA)
Breaking Capacity DC1: 6 A - 30 V DC
Ÿ
Opera ng temperature: max.+50°C
Ÿ
Max depth: 20m
Ÿ
Protec on Grade: IP 68
Ÿ
Features of automa c ac on: 1B (micro-disconnec ons in opera on)
Ÿ
Pollu on Degree: 2
Ÿ
TERMINAL CONNECTIONS:
The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protec on shall null
and void the warrany in the event the float breaks.
Emptying: (Fig.2) when black and brown wires are used, the circuit opens when float is down and closes when the
Ÿ
float is up. Note: the blue/grey wire must be insulated.
Filling: (Fig.3) when black and blue/grey wires are used, the circuit closes when float is down and opens when
Ÿ
the float is up. Note: the brown wire must be insulated.
Fig.2 emptying
Black
N
Brown
L
M
Blue
ENGLISH
High level starts the
pump
N
L
M
The tank drains
Ac va on angle: 20°
Fig.3 filling
Black
Blue
Brown
Low level stops the
pump