Filter does not run or no water flows out
Cause
No power supplied
No water in the filter
Impeller and/or shaft fitted crooked, shaft broken,
rubber bearings of shaft missing, bayonet lock on
impeller casing not positioned correctly
Impeller missing or blocked by gravel, wormgear
casing or impeller faulty
Filter capacity greatly reduced
Cause
Stopcocks levers on pump head not in "OPEN"
position
Hose connection block dirty
Hoses kinked etc.
Intake strainer blocked
Hoses blocked with sediment
Filter material heavily soiled
Filter material filled into net bag
Filter material not cleaned thoroughly
Incorrect filter material used
Pump dirty
Water does not circulate correctly
Impeller and/or shaft fitted crooked, shaft broken,
rubber bearings of shaft missing, bayonet lock on
impeller casing not positioned correctly
Too many accessories attached to hose system
Solution
Plug into power supply
Filter does not have automatic suction! Press start
button and fill filter with water (5)
Dismantle, check, replace faulty parts and re-
assemble. Check shaft and bayonet lock correctly
positioned.
Clean impeller casing, fit intact impeller
Solution
Check positions and correct them
Remove hoses and use suitable brushes to clean
hose connection block whilst in position with
stopcocks in "OPEN" position
Check hoses for kinks, constrictions etc.
Clean intake strainer
Clean hoses with cleaning brush
Clean filter material (particularly pre-filter
material).
Do not fill long-term biological filter material e.g.
JBL MicroMec, JBL Sintomec etc. in finely meshed
net bags. For special problem solutions, only use
the original CristalProfi filter material with the
appropriate foam edge.
Remove filter material from filter basket and
clean.
Fill fine filter material e.g. filterwool loosely
into the filter baskets so that water flow is not
obstructed.
Clean pump chamber, impeller and cover with
cleaning brush (10)
Repeat start procedure (5)
Dismantle, check, replace faulty parts and re-
assemble. Check shaft and bayonet lock correctly
positioned.
Accessories (e.g. UV-C clarifier etc.) reduce water
flow. Remove accessories or operate with own
separate water circulation.