Cutting copper tube
1/4t
Remove burr indoor
Copper tube
Swaging block
Ø Tube, D
Inch
mm
1/4"
6.35
3/8"
9.52
1/2"
12.70
5/8"
15.88
3/4"
19.05
R410A - Heat Pump
Fan Coil Unit
Water Source Heat Pump Unit
Nominal Cooling Capacity
Nominal Heating Capacity
Unit Weight
Fan Motor
Fan Blower
Air Flow Rate (High Speed)
Refrigerant Circuit
Liquid valve connection
Gas valve connection
Drain Pipe Connection
Air Filter
A (mm)
Imperial
Rigid
1.3
0.7
1.6
1.0
1.9
1.3
2.2
1.7
2.5
2.0
PHYSICAL DATA
Btu/h
W
Btu/h
W
kg/lb
m
3
/min
mm/in
mm/in
mm/in
1-5
Piping Connection To The Units
•
Align the center of the piping and tighten the flare nut
sufficiently with fingers.
•
Finally, tighten the flare nut with the torque wrench until
the wrench clicks.
Flare Joint
Indoor Piping
Spanar
Pipe Size mm / (in)
6.35 (1/4)
9.53 (3/8)
12.7 (1/2)
15.88 (5/8)
19.05 (3/4)
5WMWS10GR
5WMWS10GR
5WSS07AR
5WSS10AR
8094
10000
2370
2930
8800
10500
2580
3080
12 / 26.46
Permanent Split Capacitor
300 / 142
6.35 / 1/4
9.52 / 3/8
16 / 0.63
SARANET + IONIZER + DEODORIZER
Flared Tube
Flare Nut
Torque Wrench
Torque Nm / (ft - lb)
18 (13.3)
42 (31.0)
55 (40.6)
65 (48.0)
78 (57.6)
5WMWS15GR
5WSS15AR
12000
3443
12800
3750
345 / 163
12.7 / 1/2