Use Instructions; Door Opening; Door Closing - hafele Slido F-Flush51 60 Electric 400.50.038 Manual De Instrucciones

Tabla de contenido

Publicidad

To unpair the remote control from the control unit, press and release the
'REMOTE SET' button, after which the red LED will flash.
Press the 'REMOTE SET' button again and keep it pressed until the led stops
flashing. When the button is released, the red LED will flash 5 times to confirm the
unpairing.
The unpairing of a remote control completely eliminates its association with any
control unit. In order to use the remote control, it will be necessary to pair it again
using the standard procedure.
3.5 Wiring of the control unit switch
DEVICE =0 - 48V
MAX 2A
0 - 48
N/O
SWITCH
3.6 Checks
Check that each door moves correctly.
Check that the system is effective in avoiding crushing, by introducing an object between the cabinet side and the closing door.
Perform this checks in order to avoid any risk, damage or injury due to possible faults or malfunctioning of the system.

4. Use instructions

4.1 Door opening

The door opening command can be given by slightly pushing on the door or by using the remote control.
Push the door a few millimetres in its opening direction and the system will automatically detect the displacement and operate the motor until
the door reaches its open position.
Alternatively, press the button on the radio control corresponding to the door to be opened and the system will receive the signal and operate
the motor until the door reaches its open position.
In the event that the opening of a door is obstructed by another previously opened door, both doors will move simultaneously to free the
opening.

4.2 Door closing

The door closing command can be given by slightly pushing on the door or by using the remote control.
Push the door a few millimetres in its closing direction and the system will automatically detect the displacement and operate the motor until
the door reaches its closed position.
Alternatively, press the button on the radio control corresponding to the door to be closed and the system will receive the signal and operate
the motor until the door reaches its closed position.
4.3 Close all doors with a single command
To close all open or partially open cabinet doors, long press (3 seconds) one of the active remote control buttons for the configuration in use.
The system will automatically bring all doors to their closed positions.
44
The NO switch is a simple, normally open contact controlled by control unit.
No voltage output is supplied from the switch terminals.
The switch can control equipment with a nominal voltage of between 0 and 48V and a maxi-
mum current of 2A.
Wiring for control via the switch must be performed by specialized personnel according to the
wiring diagram supplied.
FREQUENCY: 433,92 MHZ
MAX POWER: 1 mW
DEVICE
SOURCE
0 - 48V
DEVICE
MAX 2A
SWITCH
DEVICE
DEVICE
00:00:03
O
N/O
I

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Slido f-flush51 60 electric 400.50.039Slido f-flush51 60 electric 400.50.486Slido f-flush51 60 electric 400.50.487Slido f-flush51 60 electric 400.50.488

Tabla de contenido