eNgliSh
Table of contents
5.0 Use .......................................................... 17
7.0 Service .....................................................19
Figures ...........................................................53
1
1.0 Relationship to the
authorities
Installation of a fireplace must be according to local codes and
regulations in each country.
All local regulations, including those that refer to national and
European standards, shall be complied with when installing the
product.
Instructions for mounting, installation and use are enclosed with
the product. Prior to using the product the installation must be
approved by a qualified person.
A product data plate in heat resistant material is located on the
heat shield under the product. This contains information about
identification and documentation for the product.
2.0 Technical data
Material:
Finish:
Fuel:
Log length, max:
Effect:
Flue outlet:
Flue pipe dimension:
Weight:
Product measures:
Technical data according to EN 13240
Nominal heat output:
Flue gas mass flow:
Recommended chimney draught:
Efficiency:
CO emission (1% O
):
2
Flue gas temperature:
Operational type:
Cast iron
Black paint, blue black enamel
Wood
40 cm
2,3 - 8,5 kW
Top, rear
Ø125 mm/123 cm
cross section
2
78 kg
See fig. 1
6,0 kW
6,9 g/sec
12 Pa
71% @ 6,1 kW%
0,28%
318
C
o
Intermittent