Temperature selection handle (W), see fold-out page VI, Fig. [17].
For individual components, see delivery specification, Fig. [VI].
The temperature is adjusted at the factory.
It must be checked, whether the set desired temperature corresponds to
the mixed water temperature at the point of discharge.
1.Open the hot and cold water supplies.
2.Open the shut-off knob (N) in the hand spray position and measure the
temperature of the water which runs out using a thermometer, see
Fig. [17].
3.Turn regulating nut (X) until the water temperature reaches 38 °C.
4.Attach temperature selection handle (W), ensuring that button (W2)
points to the left.
5.Install screw (W1) and fit cap (W3).
Temperature limitation
The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can be overridden by
pressing the button (W2).
Flow control for side spray, see Fig. [18].
Prevention of frost damage
When the domestic water system is drained, thermostats must be drained
separately, since non-return valves are installed in the hot and cold water
connections. For this purpose, the shower system must be removed from
the wall.
Maintenance
Inspect and clean all parts, replace if necessary and apply special grease
(order no. 18 012) if required.
I. Hand spray
- See enclosed hand spray operating instructionsProduct no.: 28 239
II. Overhead spray, see Fig. [19].
1.Remove screw (Y1) using a 4mm hexagon socket spanner.
2.Completely remove spray face plate (Y) and clean.
III. Side spray with non-return valve (Z), see Fig. [20].
1.Remove escutcheon (L2).
2.Remove screw (Z1) using a screwdriver.
3.Completely remove spray face plate (Z2).
4.Detach housing (Z3).
5.Remove washer (Z4) by pressing in the ball (Z5).
6.Remove ball (Z5).
7.Pull out non-return valve (Z) using pliers.
Assemble in reverse order.
When installing the washer (Z4) the ball (Z5) must be pressed slightly into
the housing.
The function of the SpeedClean nozzles is guaranteed for a period of five
years.
Simply rub SpeedClean nozzles in order to remove limescale from spray
jets of hand, overhead and side sprays, see Fig. [21].
Please pass these instructions on to the user of the fitting.
The right to make technical modifications is reserved.
Shut off the hot and cold water supply.
IV. Thermostatic cartridge, see fold-out page VI, Fig. [22].
1.Lever out cap (W3).
2.Remove screw (W1).
3.Remove temperature selection handle (W).
4.Remove clip (W4).
5.Detach stop ring (W5).
6.Remove regulating nut (X) with overload unit (X1).
7.Using a 22mm open-ended spanner, unscrew and remove thermostatic
cartridge (AC).
Assemble in reverse order. Observe the correct installation position.
Readjustment is necessary after every maintenance operation on the
thermostats (see Installation, Temperature selection handle).
V. Ceramic headpart, see Fig. [23].
1.Lever out cap (S3).
2.Remove screw (S1) and detach shut-off knob (S).
3.Detach splined adapter (U) and economy stop (T).
4.Remove sleeve (AD) and holder (AE).
5.Remove ceramic headpart (AF) using a 17mm socket spanner.
Assemble in reverse order. Observe the correct installation position.
VI. Aquadimmer, see fold-out page VII, Fig. [24].
1.Lever out cap (N3).
2.Remove screw (N1) and detach shut-off knob (N).
3.Detach splined adapter (R) and stop (P).
4.Remove Aquadimmer (AG) using a 19mm open-ended spanner.
Assemble in reverse order.
Observe the correct installation position. The dissimilar pins (AG1)
and (AG2) must engage in the corresponding apertures in the race, see
Fig. [25].
For installation, see also Installation, Shut-off knob (N).
VII. Non-return valve (AH), see Fig. [26].
1.Lever out caps (N3), (W3) and (S3).
2.Remove screws (N1), (W1) and (S1) and detach shut-off knob (N),
temperature selection handle (W) and shut-off knob (S).
3.Remove escutcheons (L2) and fixing rings (L) using installation
tool (L1).
4.Remove set screw (M1) using a 2.5mm hexagon socket spanner and
detach overhead spray (M).
5.Remove nut (K) and remove glass panel (H).
6.Remove non-return valve (AH) using a 17mm socket spanner.
Non-return valve (F1)
1.Unscrew spray hose (F).
2.Remove non-return valve (F1).
Assemble in reverse order.
Replacement parts, see fold-out page VIII (* = special accessories).
Care
Clean glass panel with commercially available glass-cleaning agents.
For further information on the care of this fitting, please refer to the
accompanying Care Instructions.
4