500 HOUR OR SEMI-ANNUAL ROUTINE
MAINTENANCE
Changing hydraulic drive oil
Hydraulic oil used for hydrostatic drive should be changed every
year or every 500 working hours. To add oil remove oil tank cap
( , [Figure 6]) from OIL TANK ( , [Figure 6]). This machine
is also equipped with a HYDRAULIC OIL RESERVE TANK ( ,
[Figure 6]).
Advised grade for hydraulic drive oil: ISO VG 46.
DX-500E: 8 liters,
DX-700E: 10 liters.
Figure 6
Checking and changing oil in eccentric shaft case
Remove OIL LEVEL/SUPPLY PLUG ( , [Figure 8]). Check
whether oil is full up to the oil supply port.
Replenish the shaft case oil (viscosity 32), if necessary.
Capacity of eccentric shaft case oil DX-500E
Hydraulic oil should be changed every year or every 500
working hours.
Figure 7
To drain shaft case oil from system and add new oil, remove
DRAIN
PLUG
( ,
[Figure 8]/[Figure 9])
completely drained. Secure drain plug and add new hydraulic oil
using OIL SUPPLY PORT ( , [Figure 7]).
0.75 liters
DX-700E
0.5 liters
until
oil
has
12-EN
Figure 8 Drain Plug DX-500E
Figure 9 Drain Plug DX-700E
Engine Oil
Check the oil level with OIL GAUGE ( , [Figure 10]). Add oil if
necessary using the ENGINE SUPPLY PLUG ( , [Figure 10]).
Care must be taken to keep correct oil level at all times.
To ensure long life and durability of engine, use only a high
quality oil (more than CB grade). Do not mix oil grades. Refer to
Kubota Engine Manual.
Using engine oil with a high degree of viscosity at low
temperatures may make the engine difficult to start. Engine oil
capacity on both DX-500E and DX-700E is 1.3 liters.