GYSPACK PRO will indicate the charge status :
After the charge, you can leave the machine connected to the socket.
Internal Batteries: advice and maintenance
These high performance batteries require particular care. Following these instructions will
prolong their effective life to the maximum.
Charge the GYSPACK initially after purchase and then after each use.
Do not use an external charger. Only use the one integrated in the GYSPACK.
Turn the battery-switch OFF during the charge, and disconnect the voltage selector to
prevent any error after a recharge.
Never short circuit the clamps when the battery-switch is turned ON.
Never connect the red clamp on the (-) of the vehicle battery, and the red clamp on the
ground of the engine. This would result in a short circuit.
Wait 3 minutes between each starting attempt. This allows the batteries voltage to rise
again, and the internal elements to cool down. If you do not wait and/or if any starting
attempt lasts for too long, you risk losing some power, and you reduce your chances of
succeeding the start on next attempts.
Troubleshooting, causes, solutions
Troubleshooting
A Buzzer produce a sound
and red light is on
The red light flashes.
Sparks are created when
connecting clamps to the
vehicle battery.
The machine cannot start
the vehicle, the red light
flashes.
GYSPACK PRO 12.24
Orange light: charging – voltage increasing
Flashing Orange light: voltage regulation (2h to 16h if batteries are
sulphated or deeply discharged)
Green light : the battery is charged.
Causes
The product detects an
inversion of polarity.
The battery voltage went
lower than 12,5V after a
start or a heavy
consumption.
The battery switch is
turned ON and/or the
voltage selector is on 12V
or 24V.
The voltage selector is in
the wrong position.
Polarity inversion.
Internal batteries are
discharged.
Many starting attempts
without recovery time.
Solutions
Check the polarity on the battery.
Red clamp to the (+) of the
battery and black clamp to the (-).
Charge the machine after the use.
The red light will turn off.
Before plugging the clamps on the
vehicle battery, turn the battery-
switch OFF, and disconnect the
voltage selector.
Check that the selected voltage
corresponds to the voltage of the
vehicle's battery
Check polarity on the battery
Recharge the machine to the
max, and try again
Wait 3 minutes between two
starting attempts.
A start should not last for more
than 5 seconds.