13.56 MHz
Upgradable readers ARC
Installation instructions
ARC-X
X: A: Standard
B: Keypad
C: Touch screen
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC EN 60950-1 Ed2) or type ES1, PS1 (according to IEC EN 62368-1) for the main supply.
Main power supply:
Range: +7 Vdc to +28 Vdc
Max. consumption at 12 Vdc:
ARC-A: 130 mA / ARC-B: 160 mA / ARC-C: 200 mA / ARC-D: 280 mA / ARC-E: 310 mA / ARC-F: 350 mA / ARC-I: 160 mA / ARC-J: 190 mA
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock and Data)
Connection:
Removable connectors 1x10 pins and 1x2 pins, thread 0.19685 inch
Protection:
IP65, excluding connectors
ASSR-1218-003E: 60 V output withstand voltage / 0.2A current rating / low on-resistance 1 Ω typical for AC/DC
Static relay:
Use a multi-conductor shielded twisted pair cable.
Max. length RS485:
328.1 ft at 9600 baud
Max. length RS232:
49.2 ft
Wiegand / Clock & Data:
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the remote system with a 0 Vdc
respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's connector or controlled by the communication protocol of the reader (W3x).
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate the tearing of
reader.
▪
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
▪
for R/S 32 and 33: the reader will perform the operations configured with the configuration card.
▪
for W32 and 33: the reader will perform the operations configured with the SSCP protocol.
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
Read-only reader, except touch screen: automatic tamper management.
Touch screen read-only reader: if the bell is activated, contact J2 is used to connect the external ring (max. 200 mA at 28 Vdc).
Read/Write reader: the relay is controlled by the SSCP/OSDP™ protocol commands.
Reader powered off. The default reader settings can be stored in internal memory accessible by UHF RFID technology. They will be taken into account when
the reader is powered on.
R and S readers are configurable with the SCB configuration card created with SECard.
▪
If the SCB is compatible with the reader's firmware, the LED lights green and the buzzer beeps five times.
If the SCB is not compatible with the reader's firmware, the LED lights red and the buzzer is activated for 1 s.
▪
Caution: set your reader with your own company key.
On power-up, the reader enters an initialization phase:
1. Activation of the white LED and buzzer for 100 ms.
For read-only readers:
2. Activation of the LED, according to the color code: Red = +10, Orange = +5, Green = +1, indicating the firmware version.
3. For serial R/S ARC only: the orange LED flashes 20 times: waiting for an update.
4. Activation of the default LED (flashes blue if no customer specific configuration).
5. ARC Screen: display of the default image and keypad activation by touching the screen.
▪
For optimal operation, the biometric sensor must be free of all traces of water. Outdoors it is recommended to install the reader under cover.
▪
The keypad is sensitive. Take off your gloves to enter your code.
▪
For the ARC screen with an activated keypad, the default mode is: display the picture on standby and activate the keyboard by pressing the screen.
© STid - 20 PA des Pradeaux FR13850 Gréasque - NI1097C13 - Page 1 sur 12 - Ed. 08/04/2019
D: Standard + Biometrics
E: Keypad + Biometrics
F: Touch screen + Biometrics
J6: Antenna connector
J7: Keypad connector
J9: Biometric connector
J14: Display connector
J2: O/C contact
Typical: 12 Vdc
1 pair AWG24 – 98.4 ft max / 2 pairs AWG24 – 196.9 ft max / 3 pairs AWG24 – 328.1 ft max
1 pair AWG20 – 164.0 ft max / 2 pairs AWG20 – 328.1 ft max
UHF default configuration settings
Read-only reader configuration
Precautions for the biometric sensor and keypad
13,56 MHz
Lecteurs évolutifs ARC
Notice d'installation
Product references
Power supply characteristics
Characteristics
Recommended cables
Buzzer / LED
Anti-tearing
Relay
Powering-up the readers
13.56 MHz
Lectores escalables ARC
Procedimiento de instalación
conforme con NOM-024 -SCFI-2013
I: Standard + 125 kHz module
J: Keypad + 125 kHz module
Connector
Type
J4
Wiegand
Clock & Data
1
0 Vdc
2
+Vcc (+7 Vdc to +28 Vdc)
3
D0
Code
4
D1
Data
5
Clock
Clock
6
NC
NC
7
NC
NC
Led 1
8
Led 2
9
Buzzer
10
US
FR
ES
RS232
RS485
NC
NC
NC
NC
NC
NC
Tx
L+
Rx
L-