j | BA 14.0197 | 11/2010
5
Electrical installation
5.1.2
Circuit proposals
Fig. 14 INTORQ BFK464 connection diagram
5.2
Bridge/half−wave rectifiers (option)
BEG−561− \\\− \\\
Bridge/half−wave rectifiers are used for the supply of electromagnetic spring−applied DC
brakes which have been released for operation with such rectifiers. Any other use is only
permitted with the explicit written approval of INTORQ.
After a defined overexcitation time, the bridge/half−wave rectifiers change from bridge
rectification to half−wave rectification. Depending on the dimensioning of the load, the
switching performance can thus be improved or the power can be derated.
32
Switch−on
K2/K4 must be switched before or at the same time as K1/K3!
|
Switch−off
Normal − AC switching
|
– K2/K4 remain closed
– K1/K3 open
Emergency stop − DC switching
|
– K1/K3 and K2/K4 are opened at the same time
BFK464XX_1−006.iso