INSTALLATION PROCEDURE
CAUTION: RISK OF PERSONAL INJURY.
This valve requires the maximum outlet temperature to be set/adjusted by the
installer.
The maximum outlet water temperature should never exceed 120 ºF (49 °C).
1. Turn off the main water supply.
2. Connect the hot water supply to the inlet marked "H" and the cold water supply
to the inlet marked "C".
Thermostatic mixing valve
mounting bracket
Supply hose
Angle stop
G1/2 compatible with 1/2 NPSM
ONLY THERMOSTATIC MIXING VALVE INCLUDED
Controller
Supply hose
Swivel coupling
Supply hose
or
Angle stop
G1/2
G1/2
Thermostatic mixing valve
- 4 -
ADJUSTING MAXIMUM OUTLET TEMPERATURE
1. Shut the water off at the stop valves.
2. To decrease temperature:
Remove cap and screw and pull handle slowly to remove.
Turn handle counter-clockwise one notch and reinstall onto cartridge.
To increase temperature:
Remove cap and screw and pull
handle slowly to remove.
Turn handle clockwise one notch
and reinstall onto cartridge.
3. Secure handle with screw and cap.
4. Open shut off valve.
5. Check water temperature.
**Repeat steps 1-5 if necessary
ADJUSTING OUTLET TEMPERATRURE
1. To decrease temprature:
Turn handle clockwise.
2. To increase temprature:
Turn handle counter-clockwise.
ACCESSING ANG CLEANING THE VALVE
1. Shut the water off at the stop
valves.
2. Disconnect supply hoses.
3. Pull out the strainer and clean it
with a brush.
4. Reinstall the clean strainer and
connect water supply hoses.
5. Open the stop valves.