Regulating the secondary air inlet will allow more control over the combustion, slowing the process down and
making the most of each firewood load.
appliance when adjusting the primary air inlet and opening the door.
Even though the correct regulation of the air inlets will be acquired through your own use and experience with
your stove, this table will allow you to get off to a good start:
COMBUSTION PHASE
Lighting of the fire
Nominal heat
Minimal heat
Reloading
NB: on days of adversary weather conditions (low atmospheric pressure, strong colds); when the chimney is very
cold, or if you have a chimney with deficient draught, one can help start the draught heating up the conduct:
1
prepare the firewood in the chimney for lighting
2
put some newspaper made into a ball on top of the deflector at the start of the flue and set fire to it.
3
After a few seconds light the fire according to instructions.
NB
To avoid overheating, the wood burner must be connected to the mains if there is a lit fire or embers.
NB The power cable must be connected by a plug to a multi-socket adaptor and it must be accessible once the
appliance has been installed. The power cable or electrical components should only be changed or replaced
by qualified personnel to avoid hazards.
4. MAINTENANCE
To clean the glass, be careful to spray the cleaning product on a cloth and clean only the glass, without
wetting the rest of the door. Window-cleaners and special products often contain chemicals that attack the
paint and the ceramic fibre seals and cause oxidation of the metal parts.
It is very important not to wet the wood burner with window-cleaner, water or special cleaning products.
Heatproof paint is not waterproof.
Clean the paintwork with a feather duster or a soft, dry cloth. If over time you want to repaint the insert, the
manufacturer makes a spray paint available from your dealer.
In order to avoid burns, always use the glove supplied with the
PRIMARAY AIR
Open 100%
Closed 100%
Closed 100%
Open only if necessary and close again
SECONDARY AIR
Open 100%
Open 100%
Regulate according to convenience (25 –
100%) open
Regulate according to convenience (25 –
100%) open
Página 27 de 43