GB
• Then close the lens and retighten the screw.
INSTALLING
Installation may only be carried out by trained professionals according to the
applicable installation regulations. Contact a licensed electrician.
ATTENTION!! Before installation, the power supply must be disconnected and
locked out.
• Loosen the screws on the side of the housing and remove the mounting
brackets.
• Install the mounting brackets to a suitable surface – always follow the
installation location requirements listed under "General Safety Information"
(s. 1-4).
• Reattach the floodlight housing to the mounting brackets but do not tighten
the screws fully.
• Loosen the screws on the back of the junction box and remove the cover.
• Loosen the cable grip screws and remove the cable grip.
• Guide the screw connection seal over the cable as well, and then insert
the cable into the junction box. Ensure the seal is seated in the cable guide
correctly – if the connecting cable is too thin, the cable guide must be
additionally sealed.
• Connect the wires according to Figure 5.
• Tighten the cable guide screw connection, install the cable grip, and tighten
the screws.
• Install the junction box cover and tighten the screws.
SETTING THE FLOOdLIGHT dIREcTION
• Loosen the screws on the sides of the mounting brackets, adjust the
floodlight direction, and then retighten all screws.
SETTING UP THE MOTION dETEcTOR
• Turn both dials (
+
) fully counter-clockwise. The floodlight turns on for
approx. 1 minute and then turns off.
• Walk the entire acquisition area. Once you leave the area, the halogen
floodlight is turned off after a time delay; upon re-entering the acquisition
area, it is turned back on.
• The motion detector light sensitivity and activation time can be individually
adjusted using the dials (
10
+
).
REPLAcING THE ILLUMINANT
You can find the technical data for the illuminant under "Technical Date" or on
the type plate attached to the floodlight housing.
• Disconnect and lock out the power supply to the floodlight. Allow the
floodlight to cool down sufficiently!
• Loosen the screw on the top of the floodlight and swing the lens forward.
• Loosen the wing nuts on top of the floodlight and swing the lens forward.
• Avoid touching it with bare hands since this causes grease stains which
lead to overheating. Use a clean, dry, lint-free cloth.
• Insert one end of the illuminant into the socket, press against it, and insert
the other end of the illuminant into the socket. Ensure that the socket is not
damaged.
• Then close the lens and retighten the screw.
cLEANING
• Disconnect and lock out the power supply to the floodlight. Allow the
floodlight to cool down sufficiently!
• Clean with a dry or slightly moist, clean, lint-free cloth and a mild detergent
if required. Do not use cleaners that contain abrasives or solvents.
• If required, the illuminant can be cleaned with a lint-free cloth moistened
with ethyl alcohol. ATTENTION! After cleaning the illuminant with ethyl
alcohol, it must be allowed to air dry for at least 20 minutes.
MAINTENANcE
• If the lens is damaged it must be replaced immediately.
• Clean any dirt from the housing or the lens immediately, since it could
cause overheating.
GB
11