DISHWASHER
AX545FE1
AE3ABREXA
AFTER SALES SERVICE DATA
• Operating instructions F/GB
• Operating instructions D/DK/NL
• Operating instructions PL/RUS
• Operating instructions E/P/GR
• Servicing guide
• Programme test SAV
•
OVERALL DESCRIPTION
• Date of manufacture
• Standards
• Capacity
• Band colour
• Installation type
• Number of push buttons
• Number of visual indicators
• Regeneration
• Programming type
ELECTRICAL DATA
• Supply voltage
• Frequency
• Maximum current density
• Overall power
• Heating power
DIMENSIONS BARE
• Width
• Height (adjustable)
• Depth
• Weight
DIMENSIONS PACKED
• Width
• Height (adjustable)
• Depth
• Weight
Brandt Customer Services
MAIN COMPONENTS
• Cycling induction motor
: 83X0122
: 83X0124
- Main winding
: 83X0123
- Auxiliary winding
: 83X0126
Auxiliary winding
: 3X2555
- Voltage
- Power
: 3X0200
- Capacitor
• Synchronous drain pump
- Ohmic value
: 09 / 2003
- Voltage
: -
- Power
: 12 table settings
- Output
: White
: Free
• Immersion heater
: 1
- Ohmic value
: 2
- Voltage
: Yes
- Power
: Electronic
- Load
• Solenoid valve
- Solenoid valve
- Voltage
: 230 V
- V1 valve output
: 50 Hz
- V2 valve output
: 16 A
: 2150 W
TEMPERATURE CONTROL
: 2040 W
Hydraulic system thermostats
The heating tunnel is protected by a fusible thermos flask 206°C
and a thermostat from 98°C
: 595 mm
: 848 - 858 mm
SECURITIES
: 600 mm
• Anti-overflow
: 44 kg
PERFORMANCE
Water (l)
: 671 mm
: 896 mm
: 661 mm
: 49 kg
Time (mn)
12
140
3X0196
TECHNICAL
FEATURES
: 95,8 / 110,7 Ω
: 199 / 230 Ω
: 23 / 26,7 Ω
: 220 / 240 V
: 90 W
: 2 µF
: 250 Ω ± 7%
: 220 / 240 V
: 30 W
: 15 l/mn
: 25 Ω
: 230 V
: 2040 W
: -
: 1 ways
: 220 V
: 5 l/mn
: -
: 47 kΩ à 25 °C
: Yes
Energy (kW/h)
1,05
01/2005
TF 1/1