8. Specifications
Model
EN
CAPACITY
INPUT
Voltage
Voltage Range
Frequency Range
OUTPUT
Voltage Regulation
Transfer Time
Waveform
Protection
BATTERY
Type & Number
Charging Time
Protection
Backup Time (est. 120W)
PHYSICAL
LCD Indicator
Dimension (DxWxH)
ENVIRONMENT
Humidity
Noise Level
Model
CAPACITY
INPUT
Voltage
Voltage Range
Frequency Range
OUTPUT
Voltage Regulation
Frequency Range
Transfer Time
Waveform
BATTERY
Type & Number
Charging Time
Protection
Backup Time (est. 240W)
PHYSICAL
LCD Indicator
Dimension (DxWxH)
ENVIRONMENT
Humidity
Noise Level
VI 750 PSW
750 VA / 480 W
Typical 2-6 ms, 10 ms max.
Short circuit and overload protection
12V/ 9Ah x 1
6 hours recover to 90% capacity
Discharge and overcharge protection
10 min
Input/output voltage, AC mode, Load level, Battery capacity
350 x 146 x 160 mm
0-90 % RH @ 0-40° C (non-condensing)
VI 1500 PSW
1500 VA / 1050 W
220/230/240 VAC
162~290 VAC
50/60 Hz (Auto sensing)
50 or 60 Hz +/-1 Hz
Typical 2-6 ms, 10 ms max.
Pure Sinewave
12V / 9Ah x 2
6 hours recover to 90% capacity
Overload, discharge and overcharge protection
18 min
Input/output voltage, AC mode, Load level, Battery capacity
397 x 146 x 205 mm
0-90 % RH @ 0-40° C (non-condensing)
Less than 55 dB
VI 1000 PSW
1000 VA / 700 W
220~240 VAC
162~290 VAC
50/60Hz±1Hz
+/-10%
Pure Sinewave
12V/ 7Ah x 2
15 min
Less than 45 dB
VI 2000 PSW
2000 VA / 1400 W
+/-10%
12V / 10Ah x 2
20 min