Descargar Imprimir esta página

Technical Data - Felisatti RHF40/1100VERT Instrucciones De Servicio

Ocultar thumbs Ver también para RHF40/1100VERT:

Publicidad

Idiomas disponibles

Idiomas disponibles

Parameter
Rated
Voltage, V~
Rated
frequency,
Hz
Rated Input , W
No-load speed (rpm), /min
No-load speed (bpm), /min
Impact Energy, J
Tool holder system
Max. drilling
Capacity, mm
-
Drill bit
-
Core bit
Ability to adjust speed
Changing the direction of tool rotation
Chiselling mode (without tool rotation)
Preset angular position of the tool
Weight according to EPTA-Procedure 01/2003, kg
Typical A-weighted emission sound pressure level(LPA),
Typical A-weighted sound power level(LWA), dB(A)
Uncertainty K, dB(A)
Triaxial vibration value (ah), m/s
hammer drilling
chiseling
Uncertainty K, m/s
2
Read the operating instructions
Protection category II power tool; double
insulated
Wear eye protection
Wear ear protection
The instructions contained in this manual must be
strictly followed, it should be carefully read and kept close
at hand to use when carrying out maintenance on the
indicated parts.
If the machine is used carefully and normal
maintenance is carried out, it will work well for a long time.
The functions and use of the tool you have bought
shall be only those described in this manual. Any other
use of the tool is strictly forbidden.
ILLUSTRATIONS
The overall look of the machine shown in Fig.1.
1 – RETAINER SDS-max®
SELECTOR
2 -
CHANGE LEVER
3 -
TRIGGER SWITCH
4 -
HANDLE
5 -
CONTROLLER KNOB
6 -
END COVER
7 -
8 -
HOUSING
9 -
SIDE HANDLE
STOPPER
10 -

TECHNICAL DATA

:
2
RHF40/1100VERT
dB(A)
List of Contents
-
Plastic Box
-
Grease tube
-
Stopper
--
Operating instructions with Safety instructions
Drilling in concrete
Chipping, chiseling, demolishing in concrete
Digging for anchor bolt
Crushing, grooving, squaring, cutting, hardening in
concrete
[Examples of application]
Heating & cooling work, piping work, wiring work,
sanitary facilities work, installation of machinery, water
supply & drainage works, interior decoration work,
installation of seats, harbor facilities work and other
engineering facilities work.
BEFORE USING THIS TOOL
WARNING! Before carrying out any work, check, for
instance, using a metal detector, that there are no electric
wires or gas or water pipes under the surfaces you wish to
work on.
Make sure the mains voltage is correct: it must be
the same as that on the speciication label. Machines with
230V can also be connected to a 220V mains supply.
Extension Cord
Use an extension cord if the distance to the power
source requires its use. Extension cord must be of
appropriate thickness and length for the supply of electric
current. Too thin or too long cord will cause voltage to drop
reducing the motor power. Use it as short as possible.
If the cord is damaged, have it repaired or replaced at
A/S center immediately.
RF40/1100VERTM
230
50
1100
235-500
1350-2870
2-7.5
2-7.5
SDS-Мах
40
105
yes
no
yes
yes
6.2
6.4
93
104
3
13.0
7.0
11.0
8.5
1.5
APPLICATIONS
5

Publicidad

loading

Este manual también es adecuado para:

Rhf40/1100vertm