Descargar Imprimir esta página

EHEIM compact 1000 Manual Del Usuario página 7

Ocultar thumbs Ver también para compact 1000:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

household waste. Take it to your local refuse
collection site.
The product is qualified in accordance with the
respective
guidelines and meets EC standards.
A
Function
a
Motor body
with protector
The immersion pump can only be used in the a-
quarium under water and must not run dry. Cable
length 1.5 m, temperature range max. 35°C. The
motor is protected against overheating.
B
Installation
Insert the two suckers into the bottom 2 openings
of the pump housing. Attach the pump below the
water surface to the inner wall of the tank.
C
Putting into operation
The flow rate can be adjusted if desired by shift-
ing the output regulator within the
max. range. The device is put into operation by
the power plug.
D
Care and maintenance
Unplug the power plug. Pull the pump housing off
the motor body to the front with strong pressure.
Take pump wheel out of its mounting.
Wash out all pump parts thoroughly and clean with
the brush set (no. 4009560).
Possible lime deposits can be removed by putting
the pump parts in vinegar for a few hours.
Then re-assemble all the parts in the appropriate
order.
national
b
Pump wheel
d
Output regulator
regulations
c
Pump housing
e
2 suckers
min. and
and

Publicidad

loading