FIAP TrommelSieve Active
Error search
Error
Possible cause
Filter does not stop automatically after
Steady contact between sensor and filter case
set time
No water comes out of the spray
Fine filter or spray nozzles are blocked
nozzles while the clean pump is
It is air in the cleaning pump
working
Filter does not start
Contact switch has no contact
Unfiltered water comes out of the outlet
Entering water runs over the rubber seal
Damaged Filter element
Blocked wastewater outlet
Wrong angle of wastewater outlet
Filter elements are not getting cleaned
Clean pressure is too low
enough
Cleaning time is too short
Filter does not start automatically to
Water level in drum is too low
clean in mode „Auto"
Wrong installation of sensor
Accessories:
Art. No.
Description
2880-1
FIAP TrommelSieve Active element 30, 40, 60, 100 Mikron
2880-2
FIAP TrommelSieve Active cleaning pump
2880-3
FIAP TrommelSieve Active spray nozzle
2880-4
FIAP TrommelSieve Active ball valve DN 100
2427
FIAP GateValve Active 110 mm
2428
FIAP GateValve Active 160 mm
Installation drawing of FIAP TrommelSieve Active gravity version.
Technische Änderungen vorbehalten. Für Druckfehler übernehmen wir keine Haftung. WEEE-Reg. Nr.: DE78152045
FIAP GmbH, Jakob Oswald Str. 16, 92289 Ursensollen
Tel: 09628 9213 0; Fax: 09628 9213 30;
Solution
Remove any objects which can cause
contact between the sensor and the
filter case
Clean fine filter and spray nozzles
Remove any air out of the cleaning
pump
Ensure the contact. Close the cover
with more pressure
Check the correct fitting of rubber
seal
Check installation of filter
Replace damaged filter elements
Correct the angle of wastewater outlet
Set a higher clean pressure
Set a longer cleaning time
Check the filter elements for
damages
Check the installation of sensor
34